Related Experiment Video
Updated: Jun 8, 2026

Author Spotlight: Advancing Cardiac Procedure Testing Prior to Embarking on Large Animal Studies
Published on: August 25, 2023
Ex-vivo evaluation of clinically-set hydraulic sealers used with different canal dryness protocols and obturation
Nawar Naguib Nawar1, Mohamed Mohamed Elashiry2,3, Ahmed El Banna4
1Department of Endodontics, Faculty of Dentistry, The British University in Egypt (BUE), 24 Hasan Elgamal street El Sherouk City, Nasr City, Cairo, 11837, Egypt. Nawar.Naguib@bue.edu.eg.
Objectives:
This 2-part randomized parallel triple-blind clinical trial adopts a unique model assessing clinically-set hydraulic calcium silicate-based sealers (HCSBS) after different root canal dryness protocols and obturation techniques.
Methods:
For the first phase of the study, 24 teeth scheduled for orthodontic extractions were allocated into four groups according to the canal dryness protocol and the obturation technique. G1 (CLC-AHP): cold lateral compaction (CLC) with AH Plus sealer, G2 (CLC-ES-SD): CLC with Endosequence (ES) after standard canal(s) dryness (SD); G3 (SC-ES-SD): matching single-cone (SC) with ES after SD; G4 (SC-ES-PD): as G3 but after partial canal(s) dryness (PD). Teeth were extracted after one month of clinical service and examined for intracanal voids by micro-CT (2D & 3D). For the 2nd phase, another 24 teeth were allocated into four groups according to the root canal dryness protocol and the HCSBS used (ES or CeraSeal (CeS)). Teeth were extracted after one month and sectioned vertically for energy dispersive X-ray (EDX)/scanning electron microscope (SEM) examination. One-way ANOVA with Games-Howell post-hoc test and Chi-square test with multiple z-tests were used for statistical analysis.
Results:
SC-PD showed the highest percentage of voids (p < 0.05). MicroCT scans as well as EDX/SEM examination showed that PD resulted in significantly larger interfacial gaps (p < 0.001) with more hydration products at the sealer/dentin interface than SD.
Conclusions:
Both tested dryness protocols allowed the hydration of HCSBS and the formation of hydration products, thus standard dryness is recommended to reduce the incidence of intracanal voids.
Clinical Relevance:
When using the single-cone obturation technique, intentional root canal moisture negatively affects the performance of HCSBS.
Protocol Registration:
http://www.
Clinicaltrials:
gov, ID: NCT05808062.
More Related Videos
03:07Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024