Related Experiment Video
Updated: Jun 9, 2025

Blast Quantification Using Hopkinson Pressure Bars
Published on: July 5, 2016
The impacts of contact explosions on ultra-high performance reinforced concrete slabs: experimental study and
Wei Zhang1,2, Jize Mao1, Bukui Zhou3
1College of Aerospace and Civil Engineering, Harbin Engineering University, Harbin, 150001, China.
Abstract:
Ultra-high performance concrete (UHPC) is becoming a prevailing construction material in protective engineering. However, an insufficient research basis causes difficulty in the anti-explosion structural design of UHPC. To investigate the blast resistance of the UHPC slab (UHPCS), contact explosion tests were carried out. UHPCS exhibited superior blast resistance and a lower threshold range of failure modes than the normal reinforced concrete slab (NRCS). Compared with the NRCS, the UHPCS reached a lower damage level under the same scaled distance and had smaller craters and spalls, fewer cracks, and an absence of cross-shaped cracks. For NRCS, failure modes of medium spall, severe spall, and perforation were reached under charges of 1.0, 1.6, and 2.2 kg. In contrast, UHPCS reached medium spall, severe spall, and perforation under charges of 1.6, 3.3, and 5.0 kg. The scaled slab thicknesses (T/W1/3) of the medium spall, severe spall, and perforation of the NRCSs were 1.17, 1.27, and 1.32 times larger than those of the UHPCSs, respectively. The formulae for predicting the spall and perforation thresholds of the UHPCSs were proposed. The reduction factors were used to evaluate the mitigation effect of the blast damage on the UHPC compared to that on the NRC. The reduction factors of the crater diameter ([Formula: see text]) and the spall diameter ([Formula: see text]) were determined to be 0.507 and 0.721, respectively. For quantitative analysis of the anti-explosion performance of UHPC, a simple estimation method for predicting the dimensions of the crater and spall of the UHPCS was proposed and verified based on the dimensional analysis method.
Related Concept Videos
Impact Strength of Concrete
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Microcracking in Concrete
Effects of Creep
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...