Related Experiment Video
Updated: Jun 9, 2025

Author Spotlight: In-Depth Morphometric Examination and Quantification of Native Lens Structure Using Whole Mount Imaging
Published on: January 19, 2024
Optical Density and Polarized Light Microscopy to confirm calcification of Intra-ocular Lens
1Head Vitreoretina and Uvea Services, Post Graduate Department of Ophthalmology, Command Hospital Air Force Agaram Post Bangalore, India.
Introduction:
Intra-ocular lens (IOL) calcification is a rare yet serious complication, presenting as clouding within the optics of IOL and necessitating IOL exchange.
Patient And Clinical Findings:
In this case, a 77-year-old male experienced gradual vision loss in his left eye (LE) over four years post-cataract surgery a decade before. His best corrected visual acuity (BCVA) was 3/60 in the LE, with the anterior segment displaying a clear cornea but an opacified IOL within the capsular bag. Ultrasound biomicroscopy (UBM) revealed hyperechoic reflections from the IOL in the LE. ImageJ software used on UBM images indicated a significant difference in optical density (OD) compared to the right eye (RE).
Results:
The patient was diagnosed with IOL calcification in LE, and underwent anterior vitrectomy and IOL exchange with sulcus-placed IOL with optic capture in the capsular bag, resulting in an improved visual acuity of 6/18. Microscopic examination of explanted IOL revealed whitish calcium carbonate crystal deposits on the IOL, which were visible under polarized light.
Conclusions And Significance: