Which failures do patient-specific quality assurance systems need to catch?
Related Experiment Video
Updated: Jun 9, 2025

Author Spotlight: Microbial Control and Monitoring Strategies for Cleanroom Environments and Cellular Therapies
Published on: March 17, 2023
Jennifer O'Daniel1, Victor Hernandez2, Catharine Clark3,4,5
1Duke University School of Medicine, Durham, North Carolina, USA.
Background:
The Joint AAPM-ESTRO TG-360 is developing a quantitative framework to evaluate treatment verification systems used for patient-specific quality assurance (PSQA). A subgroup was commissioned to determine which potential failure modes had the greatest risk to treatment quality and safety, and therefore should be evaluated as part of the PSQA verification.
Purpose:
To create an extensive database of potential radiotherapy failure modes that should be detected by PSQA and to determine their relative importance for maximizing treatment quality.
Methods:
The subgroup consisted of eight physicists from seven countries, including representatives from three international quality assurance groups. We collected error reports from RO-ILS, SAFRON, AAPM TG publications, and other literature, including international audits. We focused on the subset of failure modes that impact whether the planned dose matches the dose received by the patient. We performed a failure-mode-and-effects analysis (FMEA), estimating the severity (S), occurrence (O), and detectability (D) of each failure mode. Detectability was scored assuming that PSQA was not done but other routine clinical QA was performed, which allowed us to see the importance of PSQA for detecting each specific failure mode. We analyzed the risk priority number (RPN = O*S*D), O*S, and severity rankings to determine the priority of each failure mode.
Results:
We collected 394 error reports, which we categorized into 33 failure modes that underwent FMEA. Five failure modes were in the top ranks for both RPN and O*S analysis: four involving treatment planning system (TPS) commissioning and one regarding patient model errors. The highest-ranking RPN failure modes were: TPS algorithm limitations, TPS commissioning errors [multileaf collimator (MLC) modeling, output factor, percent-depth-dose/tissue-maximum-ratio (PDD/TMR), off-axis factor], and patient weight variation. The highest O*S failure modes were similar, with the addition of external patient position variation and incorrect linear accelerator isocenter and cGy/monitor units calibration. RPN and O*S analyses prioritized failure modes that impacted multiple patients with high occurrence and detectability scores, while severity analysis gave higher priority to single-patient modes with high severity scores. The highest-ranking severity modes were MLC sequence deletion, collision, and TPS isocenter incorrect.
Conclusion:
We have developed a list of failure modes critical to be detected during PSQA and ranked them in order of importance. The top failure modes emphasize the importance of utilizing a variety of treatment verification systems for PSQA, from secondary dose calculation through in-vivo dosimetry, in order to detect all possible errors. For failure modes in the top quartile, PSQA is critical. Without adequate PSQA, these errors may go undetected unless caught by an external audit. This analysis can be useful for optimizing PSQA workflows and for designing evaluations of treatment verification systems, and will be used by the Joint AAPM-ESTRO TG-360 to determine an appropriate validation strategy.
More Related Videos
Related Concept Videos
Quality Assurance
Errors occurring during blood pressure monitoring
Several factors...
Documentation of Nursing Diagnosis
In some settings, data-driven computerized decision support systems are in place, allowing for more accurate nursing diagnoses. The database within one of these systems includes diagnostic labels defining characteristics, activities, and indicators for nursing. A nurse enters...
Guidelines and Strategies for Safe Computer Charting
Maintain Confidentiality and Security:
Health Information Technology and Healthcare Information System
Health Information Technology, commonly called HIT, integrates advanced information systems and technology in healthcare settings. Its primary functions include:
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...