Related Experiment Video
Updated: Jun 9, 2025

11:01
SSVEP-based Experimental Procedure for Brain-Robot Interaction with Humanoid Robots
Published on: November 24, 2015
13.1K
Corrections to "Enhancing Detection of Control State for High-Speed Asynchronous SSVEP-BCIs Using Frequency-Specific
Summary
A formula in a previous article was presented incorrectly due to an editing error. This erratum provides the corrected formula for accurate scientific reference.
Area of Science:
- Scientific communication
- Publication ethics
Background:
- Previous research article [1] contained a formula error.
- Formula editing errors can impact scientific accuracy.
Purpose of the Study:
- To correct an incorrectly presented formula in article [1].
- To ensure the accuracy of published scientific information.
Main Methods:
- Identification of the formula error in article [1].
- Correction of the formula through a rigorous editing process.
Main Results:
- The previously published formula (1) has been identified as incorrect.
- A corrected version of formula (1) is provided.
Conclusions:
- Accurate formula presentation is crucial for scientific integrity.
- This correction ensures the reliability of the referenced research.
Related Concept Videos
Frequency-Domain Interpretation of PD Control
94
Proportional-Derivative (PD) controllers are widely used in fan control systems to improve stability and performance. A fan control system can be effectively represented using a Bode plot to illustrate the impact of a PD controller through its transfer function. The Bode plot visually conveys how PD control modifies the fan's response across various frequencies, providing a frequency domain interpretation of the controller's behavior.
The proportional control gain, combined with the...
The proportional control gain, combined with the...
94
Time-Domain Interpretation of PD Control
84
Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
Consider the example of control of motor torque. Initially, a positive...
84
Time and frequency -Domain Interpretation of Phase-lead Control
79
Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
79
Time and frequency -Domain Interpretation of Phase-lag Control
87
Phase-lag controllers are widely used in control systems to improve stability and reduce steady-state errors. A dimmer switch controlling the brightness of a light bulb serves as a practical example of phase-lag control, gradually adjusting the bulb's brightness. Mathematically, phase-lag control or low-pass filtering is represented when the factor 'a' is less than 1.
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
87
IR Frequency Region: Fingerprint Region
773
IR spectra are divided into two main regions: the diagnostic region and the fingerprint region. The diagnostic region of the spectrum lies above 1500 cm−1. The absorptions resulting from single-bond vibrations of the N–H, C–H, and O–H stretch at higher wavenumbers and appear on the left side of the spectrum. The stretching absorptions of the C≡C and C≡N occur between 2100–2300 cm−1. In contrast, those arising from stretching absorptions of the...
773
Time and frequency -Domain Interpretation of PI Control
107
Proportional-Integral (PI) controllers are essential in many control systems to improve stability and performance. They are commonly used in everyday devices like thermostats to enhance system damping and reduce steady-state error. When the zero in the controller's transfer function is optimally placed, the system benefits significantly in terms of stability and accuracy.
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...