Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
Predialysis central arterial waveform and blood pressure changes during hemodialysis
Yoshio Iwashima1,2, Hiromichi Fukushima3, Nobuyuki Nakano4
1Department of Internal Medicine, Kansai Medical University Kori Hospital, 8-45 Kori Hon-douri chou, Neyagawa, Osaka, Japan. iwashimy@kouri.kmu.ac.jp.
Abstract:
To investigate the predictive value of the central arterial waveform for intradialytic blood pressure (BP) change, a total of 152 hemodialysis patients (mean age 68 years) on a thrice-weekly hemodialysis schedule were enrolled, and at both the first and second session of the week, BP and central arterial waveform were measured every 30 min during hemodialysis. In both sessions, a 1-standard deviation increase in baseline subendocardial viability ratio (SEVR), an index of subendocardial perfusion, as well as in baseline systolic BP (SBP) was an independent predictor of maximum SBP decrease ≥ 30 mmHg during hemodialysis. When divided into four groups based on the respective median level of SEVR in the SBP ≥ median and SBP < median groups, intradialytic SBP change was different among the subgroups. Multiple logistic regression analysis revealed that, compared with the SBP < median; low SEVR group, the SBP < median; high SEVR group had lower risk, and the SBP ≥ median; low SEVR group had higher risk of SBP decrease ≥ 30 mmHg, but the risk did not differ from that in the SBP ≥ median; high SEVR group. Predialysis subendocardial perfusion evaluated by SEVR was associated with the maximum intradialytic BP decrease, and evaluation of the central arterial waveform could be used as complementary screening for intradialytic BP change.
More Related Videos
Related Concept Videos
Hypertension and Regulation of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...
Assessment of blood pressure in brachial artery(two-step method)