High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Impact of CT attenuation correction on viable myocardium detection in combined SPECT and PET/CT: A retrospective
Fukai Zhao1, Yue Chen1, Jiaming Zhao2
1Department of Nuclear Medicine, TEDA International Cardiovascular Hospital, Tianjin University, Tianjin, P.R. China.
Abstract:
The influence of computed tomography attenuation correction (CTAC) on the accuracy of diagnosing viable myocardium using Tc-99m-MIBI dedicated cardiac cadmium-zinc-telluride (CZT) single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) combined with F-18-FDG Positron Emission Tomography/Computed Tomography (PET/CT) metabolic imaging, compared with conventional SPECT MPI, remains to be fully elucidated. To evaluate the impact of CTAC on the accuracy of diagnosing viable myocardium using Tc-99m-MIBI dedicated cardiac CZT SPECT MPI combined with F-18-FDG PET/CT, compared to conventional SPECT MPI. 193 patients underwent CZT SPECT and F-18-FDG PET/CT imaging, while 39 patients underwent conventional SPECT and F-18-FDG PET/CT imaging, with both groups utilizing CT for attenuation correction. The injured myocardium (hibernating and scarring) was quantified using the Q.PET software. After CTAC, both groups showed significant improvements in perfusion of the injured myocardial areas, particularly in the inferior wall (INF). The reduction in perfusion was more notable in the CZT SPECT group than that in the conventional group, particularly in the inferior and lateral walls. Among patients with large cardiac chambers, those undergoing MPI with CZT, with normal weights, or males, hibernating myocardium (HM) and scar post-CTAC reductions were particularly significant in the INF. If HM ≥ 10% is considered an indicator for recommended revascularization, among the 87 patients without prior cardiac bypass, 25 (28.7%) might not require revascularization treatment. Dedicated cardiac CZT SPECT and conventional SPECT MPI combined with F-18-FDG PET/CT significantly influenced the assessment of viable myocardium. The impact of CTAC was more profound in dedicated cardiac CZT SPECT, particularly in the INF region. CTAC significantly enhances the accuracy of viable myocardial assessment and may influence clinical decisions regarding revascularization therapy. Therefore, CTAC should be routinely used in dedicated cardiac CZT SPECT MPI combined with F-18-FDG PET/CT for myocardial viability diagnosis.
More Related Videos
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET