Improving culprit artery identification with intraprocedural cone-beam CT aortography and its clinical impact in
Byeong-Kwon Shin1, Kun Yung Kim2, Young-Min Han1,3
1Department of Radiology, Jeonbuk National University Hospital, Jeonju, Korea.
Objective:
To evaluate the impact of intraprocedural cone-beam CT (CBCT) aortography on culprit artery identification and clinical outcomes in patients undergoing bronchial artery embolization (BAE).
Materials And Methods:
Two hundred eighty-two patients with 317 BAE procedures were retrospectively reviewed. Patients who underwent preprocedural chest CT angiography (CTA) without intraprocedural CBCT aortography were categorized as Group A (n = 177). Patients who underwent both preprocedural chest CTA and intraprocedural CBCT aortography were categorized as Group B (n = 105). Whether CBCT can provide improved culprit artery identification and whether this improvement has a clinical impact were evaluated by comparing the two Groups.
Results:
In Group B, CBCT aortography detected more culprit non-bronchial systemic arteries originating from the subclavian arteries compared to chest CTA (16 vs 3, p = 0.026), and the average number of embolized vessels was significantly higher than in Group A (2.47 ± 1.61 vs 2.03 ± 1.17, p = 0.016), while the procedure time was shorter (37.4 ± 22.0 vs 43.6 ± 22.7 min, p = 0.024). The recurrent hemoptysis rate was lower in Group B (17.5% vs 8.7%, p = 0.041), and the proportion of patients requiring subsequent procedures was significantly lower (12.4% vs 4.8%, p = 0.035). The changes in estimated glomerular filtration rate before and 3 days after the procedure (0.1 ± 12.8 vs 0.3 ± 11.0 mL/min/1.73 m2, p = 0.909) and total dose area product (DAP, 6119.5 ± 5725.7 vs 6906.2 ± 5978.6 uGym2, p = 0.279) were not significantly different between the two groups.
Conclusion:
BAE with intraprocedural CBCT aortography enabled the embolization of more culprit arteries, leading to lower recurrent hemoptysis rates without increasing the risk of renal deterioration and radiation hazards when compared to procedures without it.
Key Points:
Question Does intraprocedural CBCT aortography improve culprit artery detection and clinical outcomes in BAE for hemoptysis? Findings CBCT aortography significantly improved the detection of additional culprit arteries, especially from non-bronchial systemic arteries, increasing the number of vessels treated during BAE. Clinical relevance Using CBCT aortography during BAE results in better long-term outcomes by reducing recurrent hemoptysis and the need for additional procedures, without increasing the risk of renal impairment.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...