Related Experiment Video
Updated: Jun 9, 2025

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Utility of arterial to end-tidal carbon dioxide gradient as a severity index in critical care
Kyung Sook Hong1, Jae Gil Lee2, Tae Yoon Kim1
1Division of Critical Care Medicine, Department of Surgery, Ewha Womans University Seoul Hospital, Ewha Womans University College of Medicine, Seoul, South Korea.
Background:
The arterial to end-tidal carbon dioxide gradient (P [a-Et] CO2) reveals the ventilation-perfusion (V/Q) status of critically ill patients. V/Q mismatch has several causes and affects the clinical outcomes of critically ill patients. We investigated the relationship between P (a-Et) CO2 and the clinical outcomes in critically ill patients.
Methods:
Critically ill patients (n = 1,978) on mechanical ventilation and capnography in the intensive care units of two institutions were enrolled and categorized into three groups: P (a-Et) CO2 ≤10 mmHg (low group), 10 mmHg < P (a-Et) CO2 ≤ 20 mmHg (medium group), and 20 mmHg < P (a-Et) CO2 (high group).
Results:
The Acute Physiology and Chronic Health Evaluation II score was 29.5 ± 8.1, 31.3 ± 8.2, and 33.3 ± 8.7 in the low, medium, and high groups, respectively (p < 0.001). Overall mortality rates were 25.5 %, 35.6 %, and 52.8 % in the low, medium, and high groups, respectively (p < 0.001). The odds ratio was 1.456 (95 % confidence interval [CI]: 1.117-1.897, p = 0.002) and 2.320 (95 % CI: 1.635-3.293, p < 0.001) for the medium and high groups, respectively, with the low group as a reference. The area under the receiver operating characteristic curve of P (a-Et) CO2 for overall mortality was 0.604 (p < 0.001).
Conclusions:
P (a-Et) CO2 is a simple, easily accessible indicator that potentially impacts patient care and outcomes as an independent marker for assessing disease severity and predicting mortality, especially in non-respiratory critical care scenarios.
More Related Videos
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and...
Acute Respiratory Failure-IV
Acute Respiratory Failure-III
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to...
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...