Abstract:
High-altitude electromagnetic pulse (HEMP) has attracted considerable attention for its influence on electrical equipment. HEMP is divided into three parts: early time HEMP (E1), intermediate-time HEMP (E2), and late-time HEMP (E3). Most studies focused on E1 alone, while few investigated others. However, the electrical equipment may be disturbed by more than one part since these three parts co-exist in a HEMP environment. The pulse current injection (PCI) test is an effective immunity test method for evaluating the sensitivity and susceptibility of electrical equipment. To investigate the responses of electrical equipment excited by the consecutive E1 and E2 and compare with those under the individual E1 or E2, this paper builds a PCI platform that can carry out PCI tests with the consecutive E1 and E2 conducted current. To output the E1 current and the E2 current consecutively, which exhibit significant differences in the rise time (20 ns and 1.5 μs), peak current (2500 and 250 A), and full width at half maximum (FWHM, 500-550 ns and 3-5 ms), an E1&E2 coupler with a fast-closing high-current trigger switch is designed in this paper. Finally, some 10-kV epoxy insulators are tested in the developed platform, which shows the capacity of the proposed platform to test the immunity of electrical equipment with the consecutive E1 and E2 conducted current.
More Related Videos
Related Concept Videos
Insulation Coordination
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Capillary Electrophoresis: Instrumentation
Overcurrent Relays
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.