Related Experiment Video
Updated: Jun 8, 2025

Invasive Hemodynamic Characterization of the Portal-hypertensive Syndrome in Cirrhotic Rats
Published on: August 1, 2018
Changes in portal pulsatility index induced by a fluid challenge in patients with haemodynamic instability and
Martin Ruste1,2,3, Rehane Reskot4, Rémi Schweizer4,5
1Service d'anesthésie-réanimation, Hôpital Louis Pradel, Hospices Civils de Lyon, 59, Boulevard Pinel, 69394, Lyon Cedex, Bron, France. martin.ruste@chu-lyon.fr.
Background:
It is uncertain whether fluid administration can improve patients with systemic venous congestion and haemodynamic instability. This study aimed to describe the changes in systemic venous congestion and peripheral perfusion parameters induced by a fluid challenge in these patients, and to analyse the influence of the fluid responsiveness status on these changes.
Methods:
The study is a single-centre prospective cohort study of 36 critically ill ICU patients with haemodynamic instability and a maximum vena cava diameter ≥ 20 mm. Changes in cardiac index during a fluid challenge (4 mL/kg of lactated Ringer's solution during 5 min) assessed by pulse contour analysis, central venous pressure, ultrasound systemic congestion parameters (portal venous flow pulsatility index, supra hepatic and intrarenal venous Doppler), and peripheral perfusion parameters (capillary refill time and peripheral perfusion index) were assessed in the overall population. All these data were compared between patients presenting a cardiac index increase > 10% during the fluid challenge (fluid responders) and the others (fluid non-responders).
Results:
Twenty-eight (78%) patients were admitted for postoperative care following cardiac surgery; their mean ± SD left ventricular ejection fraction was 42 ± 9% and right ventricular dysfunction was found in at least 61% of the patients. The mean ± SD SOFA score was 9 ± 3. Thirteen (36%) patients were fluid responders. The fluid challenge administration induced a significant increase in portal pulsatility index, VExUS score, and central venous pressure without significant difference of these changes between fluid responders and non-responders. No significant change in perfusion parameters was observed.
Conclusion:
Fluid administration in patients with haemodynamic instability and systemic venous congestion worsens venous congestion regardless of the fluid responsiveness status, without improving perfusion parameters.
Related Concept Videos
Esophageal Varices-II: Clinical Features and Management
In the initial assessment, a thorough review of the patient's medical history is vital to identify risk factors such as liver disease, alcohol...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Measurement of Blood Pressure
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Esophageal Varices-I: Introduction
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....