Experimental performance verification of an intelligent detection and assessment scheme for disturbances and
1Misr University for Science and Technology (MUST), College of Engineering Science & Technology, Department of Electrical Power and Machines Engineering (PME), 6Th of October City, Giza, Egypt. mohandes_ragab@yahoo.com.
Abstract:
In this article, power quality disturbances, such as voltage and current unbalances, series and shunt faults, are monitored in three-phase synchronous machines. Because the imbalances affect machine efficiency and service life, it is essential to figure out whether the three-phase voltages/currents are balanced or unbalanced. An integrated detection algorithm is proposed to detect the unbalanced voltages/currents and various abnormal conditions precisely and quickly, which is based on the coherence estimator. Most existing detection methods require more than one cycle time to determine the contingency conditions, while the proposed technique detects these situations in a fast and discrete protection system. The suggested scheme acquires instantaneous measurements of the three-phase voltages and currents taken at the synchronous machine terminals in order to calculate fifteen coherence coefficients that are utilized to detect and assess any unbalance or trouble accurately and swiftly. A new proposal for imbalance and disturbance indicators based on the coherence estimators is developed in this study. Multiple test cases have been conducted to validate the proposed algorithm capabilities using a real power system, which includes a motor-generator set, a three-phase load and measurement transformers. The experimental results have been revealed that the relay reliability and accuracy percentages have been found to be 98.28% and 98.52%, respectively. The quantitative findings of the imbalance and disturbance assessment are recorded.
More Related Videos
11:06A Human-machine-interface Integrating Low-cost Sensors with a Neuromuscular Electrical Stimulation System for Post-stroke Balance Rehabilitation
Published on: April 12, 2016
09:04Uncovering Beat Deafness: Detecting Rhythm Disorders with Synchronized Finger Tapping and Perceptual Timing Tasks
Published on: March 16, 2015
Related Concept Videos
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Simplified Synchronous Machine Model
In this model, each generator is connected to a...
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Power System Three-Phase Short Circuits
Three-Phase Voltages
Generation of Three-Phase Voltage
As the rotor...