Evaluating Postural Control and Lower-extremity Muscle Activation in Individuals with Chronic Ankle Instability
Published on: September 18, 2020
Smartphone Proprioception for Ankle Navigation (SPAN): Reliability and Effect of Position Exposure Time
Xiaojian Shi1, Charlotte Ganderton1,2,3, Roger Adams3,4
1School of Health and Biomedical Sciences, Royal Melbourne Institute of Technology University, Bundoora, Victoria, Australia.
Shorter joint position exposure times (PETs) improve ankle proprioception reliability. The Smartphone Proprioception for Ankle Navigation (SPAN) device offers a reliable method for assessing ankle proprioception, especially at shorter PETs.
Area of Science:
- Biomechanics
- Motor Control
- Sports Science
Background:
- Ankle proprioception is crucial for balance and injury prevention.
- Assessing ankle proprioception typically requires specialized equipment.
- Understanding the impact of testing parameters on reliability is essential for clinical application.
Purpose of the Study:
- To investigate the effect of different joint position exposure times (PETs) on ankle discriminative acuity, performance, and measurement consistency.
- To evaluate the reliability of the Smartphone Proprioception for Ankle Navigation (SPAN) device across various PETs.
- To determine the optimal PET for reliable ankle proprioception assessment using SPAN.
Main Methods:
- Twenty-four participants were tested using the novel Smartphone Proprioception for Ankle Navigation (SPAN) device.
- Four different PETs (0.25s, 0.5s, 0.75s, 1s) were administered in a random sequence.
- Participants were re-tested within one week to assess measurement consistency and reliability (ICC, SEM, MDC90).
Main Results:
- Ankle proprioception performance improved with prolonged PET, with the non-dominant limb showing better performance than the dominant limb.
- A PET of 0.25s demonstrated good to excellent reliability (ICC = 0.897), while longer PETs showed poor to moderate reliability.
- Prolonged PETs improved performance but amplified inter-occasion variability, potentially due to increased cognitive load.
Conclusions:
- A PET of 0.25s provides the most reliable assessment of ankle proprioception using the SPAN device.
- While longer PETs enhance ankle proprioceptive performance, they reduce measurement consistency.
- The SPAN device presents a cost-effective and accessible tool for clinical assessment of ankle proprioception.