Abstract:
On construction sites impacted by particulate matter and hazardous gases, portable integrated air filtration equipment with high efficiency, minimal pressure drops and ammonia (NH3) alarms is critical. Triboelectric nanogenerators (TENG) present a sustainable solution by generating self-powered electricity to fulfill these requirements. In this study, we synthesized zeolitic imidazolate framework-8 (ZIF-8) in situ on the surface of titanium carbide (Ti3C2Tx) to create Ti3C2Tx/ZIF-8, grafted it onto cellulose diacetate via tetraethyl orthosilicate, and ultimately developed a cellulose-based nanofibrous membrane through electrospinning, combining it with a negative triboelectric material to construct a self-powered TENG-based mask. The device achieved a balance between a low pressure drop (61 Pa) and high filtration efficiency (99.21 %, 99.71 %, and 99.98 % for PM0.3, PM0.5, and PM1, respectively). Furthermore, the device responds swiftly to NH3; at a concentration of 100 ppm NH3, it achieves a rapid response rate of 83 %, with a response/recovery time as low as 12/14 s. Notably, the device retains its rapid sterilization capability within a short duration (20 min) and demonstrates remarkable stability across its various performance metrics, even after multiple washes. This study presents a novel approach to the development of multi-use, self-powered wearable devices featuring excellent air filtration performance and NH3 detection capabilities.
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...