Brett Dixon1, Samuel Cohler1, Jeffery DeGrauw2
1Kirk Kerkorian School of Medicine, University of Nevada, Las Vegas, Las Vegas, USA.
Abstract:
One-lung ventilation presents unique challenges for the anesthesiologist. We present a case where the patient underwent robotic bronchoscopy to mark the lesion locations before bilateral wedge resections and a unilateral lobectomy. An 8.5 mm endotracheal tube was used to facilitate the robotic bronchoscopy. Subsequently, an EZ-Blocker double-sided bronchial blocker was placed to selectively isolate each lung during different phases of the procedure. This clinical situation required specific equipment, rather than a traditional double-lumen tube or a one-sided bronchial blocker, to efficiently manage the patient.