Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Controlled-Current Coulometry: Overview01:27

Controlled-Current Coulometry: Overview

169
Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
169
MOS Capacitor01:25

MOS Capacitor

711
A Metal-Oxide-Semiconductor (MOS) capacitor is a fundamental structure used extensively in semiconductor device technology, particularly in the fabrication of integrated circuits and MOSFETs (metal-oxide-semiconductor field-effect transistors). The MOS capacitor consists of three layers: a metal gate, a dielectric oxide, and a semiconductor substrate.
The metal gate is typically made from highly conductive materials such as aluminum or polysilicon. Beneath the metal gate lies a thin layer of...
711
Controlled-Potential Coulometry: Electrolytic Methods01:17

Controlled-Potential Coulometry: Electrolytic Methods

145
Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential...
145
Capacitors01:15

Capacitors

416
Capacitors play a crucial role in car radios, where they filter and store frequencies to ensure clear signal reception. Essentially serving as energy storage devices, capacitors store energy within their electric field and are composed of two parallel conducting plates separated by a dielectric.
When a voltage source is connected to a capacitor, positive and negative charges accumulate on the opposite plates. This accumulation generates a potential difference that equals the product of the...
416
Capacitor in an AC Circuit01:23

Capacitor in an AC Circuit

2.6K
A capacitor is charged by passing an electric current through it, which causes the plates to start accumulating an electrostatic charge. Since the strength of the charging current is maximum when the capacitor plates are uncharged and gradually decreases exponentially until the capacitor is fully charged, the charging process is neither instantaneous nor linear. The property of a capacitor to store a charge on its plates is called its capacitance.
Consider a purely capacitive circuit consisting...
2.6K
Interfacial Electrochemical Methods: Overview01:06

Interfacial Electrochemical Methods: Overview

221
Interfacial electrochemical methods focus on the phenomena occurring at the boundary between an electrode and a solution, as opposed to bulk methods that concentrate on the solution's overall properties. These interfacial methods are classified as either static or dynamic based on the presence of a nonzero current in the electrochemical cell and the consistency of analyte concentrations. Static methods, such as potentiometry, measure the cell's potential without any significant current...
221

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Transient and Regulated Cycles of Chemically Driven Disassembly and Reassembly in Anion-Driven Supramolecular Polymers.

Journal of the American Chemical Society·2026
Same author

Self-assembly and Lateral Cobalt Coordination of a Fivefold Symmetric Cyanostar Macrocycle on an Au(111) Surface.

Chemistry (Weinheim an der Bergstrasse, Germany)·2025
Same author

Anion Binding by Macrocyclic Receptors: Computational Landscape of 1:1 and 2:1 Stoichiometries.

Journal of computational chemistry·2025
Same author

Multi-Ion Complexes and Competition from Bulky BArF<sup>-</sup> Anions for Chloride Binding in Ion Pairing Conditions.

The Journal of organic chemistry·2025
Same author

Bambusuril Small-Molecule Ionic Isolation Lattices for Exciton Coupled Dimers and Dicationic Fluorophores.

Journal of the American Chemical Society·2025
Same author

Flexible point-of-use phosphate electrochemical sensors based on electrodeposited molybdenum oxide.

Materials horizons·2025

Related Experiment Video

Updated: Jun 8, 2025

Author Spotlight: Microfluidic Channel-Based Soft Electrodes and Their Application in Capacitive Pressure Sensing
05:57

Author Spotlight: Microfluidic Channel-Based Soft Electrodes and Their Application in Capacitive Pressure Sensing

Published on: March 17, 2023

2.1K

A focus on capacitive cation sensing under flow: play it again SAM.

Debapriya Gupta1, Amar H Flood1

  • 1Department of Chemistry, Indiana University 800 East Kirkwood Avenue Bloomington IN 47405 USA aflood@iu.edu.

Chemical Science
|November 4, 2024
PubMed
Summary

This study introduces reagentless electrochemical sensing by combining capacitance spectroscopy and continuous flow assays. The method allows real-time monitoring of host-guest binding events with high sensitivity and kinetic information.

More Related Videos

Sensitivity Enhancement of Soft Capacitive Pressure Sensors Using a Solvent Evaporation-Based Porosity Control Technique
10:28

Sensitivity Enhancement of Soft Capacitive Pressure Sensors Using a Solvent Evaporation-Based Porosity Control Technique

Published on: March 24, 2023

1.0K
Sensing of Barrier Tissue Disruption with an Organic Electrochemical Transistor
11:17

Sensing of Barrier Tissue Disruption with an Organic Electrochemical Transistor

Published on: February 10, 2014

11.7K

Related Experiment Videos

Last Updated: Jun 8, 2025

Author Spotlight: Microfluidic Channel-Based Soft Electrodes and Their Application in Capacitive Pressure Sensing
05:57

Author Spotlight: Microfluidic Channel-Based Soft Electrodes and Their Application in Capacitive Pressure Sensing

Published on: March 17, 2023

2.1K
Sensitivity Enhancement of Soft Capacitive Pressure Sensors Using a Solvent Evaporation-Based Porosity Control Technique
10:28

Sensitivity Enhancement of Soft Capacitive Pressure Sensors Using a Solvent Evaporation-Based Porosity Control Technique

Published on: March 24, 2023

1.0K
Sensing of Barrier Tissue Disruption with an Organic Electrochemical Transistor
11:17

Sensing of Barrier Tissue Disruption with an Organic Electrochemical Transistor

Published on: February 10, 2014

11.7K

Area of Science:

  • Electrochemistry
  • Supramolecular Chemistry
  • Analytical Chemistry

Background:

  • Electrochemical sensing offers sensitive detection but often requires reagent addition.
  • Real-time monitoring of binding kinetics is crucial for understanding molecular interactions.

Purpose of the Study:

  • To develop a reagentless electrochemical sensing platform for real-time host-guest binding analysis.
  • To integrate capacitance spectroscopy with continuous flow systems for enhanced sensitivity and kinetic information.

Main Methods:

  • Utilized capacitance spectroscopy coupled with a continuous flow assay.
  • Employed self-assembled monolayers (SAMs) of benzo-15-crown-5 receptors on electrode surfaces.
  • Analyte injection induced ion recruitment, detected as changes in capacitance.

Main Results:

  • Achieved reagentless electrochemical sensing with sensitive detection of analytes.
  • Demonstrated real-time monitoring of binding and debinding kinetics.
  • Regeneration of receptors by electrolyte injection allowed for repeated measurements.

Conclusions:

  • The integrated system provides a sensitive and continuous method for studying interfacial host-guest binding.