FRED X flow diversion stenting for unruptured intracranial aneurysms: US multicenter post-market study
Philipp Hendrix1, Sina Hemmer2, Georgios S Sioutas3
1Department of Neurosurgery, Geisinger, Danville, Pennsylvania, USA hendrix.philipp@gmail.com.
Background:
The Flow Re-direction Endoluminal Device (FRED) X is a next generation flow-diverting stent for treating intracranial aneurysms. Its surface modification (X technology) aims to minimize device thrombogenicity. Early post-market multicenter data from the US are lacking.
Methods:
We conducted a retrospective multicenter analysis of consecutive FRED X procedures performed to treat unruptured intracranial aneurysms at four US centers (March 2022 to January 2024). Cases with ruptured aneurysms or extracranial aneurysm location were excluded (n=10). We assessed patient and aneurysm characteristics, antithrombotic management, safety events, and both clinical and angiographic (effectiveness) outcomes.
Results:
In this cohort, 101 patients underwent FRED X stenting for 117 aneurysms. Most aneurysms were saccular in shape (95.7%) and located at the C6-C7 segments of the internal carotid artery (72.6%). Thromboembolic events occurred in 5.9% of the cases, leading to one instance of permanent procedure related morbidity (1.0%). No procedure related mortality (0%) was observed. Device related issues were recorded in 2.0% of cases. At the 6 month follow-up, complete aneurysm occlusion was achieved in 58% of aneurysms. At the last available follow-up (6-12 months), 74.8% of aneurysms were adequately occluded.
Conclusions:
FRED X stenting for unruptured intracranial aneurysms demonstrated low rates of neurological morbidity and periprocedural complications. Early aneurysm occlusion rates were appropriate, but further mid-term and long term follow-up is required. These findings support the early safety and effectiveness of the FRED X device for intracranial aneurysm treatment.
More Related Videos
11:00Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016
04:08Fluorescence Angiography for Evaluation of Aneurysm Perfusion and Parent Artery Patency in Rat and Rabbit Aneurysm Models
Published on: July 24, 2019
Related Concept Videos
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Urodynamic Studies: Uroflowmetry