Impact of light polarization on laser speckle contrast imaging with a custom phantom for microvascular flow
Nasrin Amini1, Ali Esteki1, Mohsen Ahmadi1
1Department of Medical Physics & Biomedical Engineering, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Abstract:
Laser speckle contrast imaging (LSCI) is a non-invasive, powerful, and cost-effective imaging technique that has seen widespread adoption across various medical fields, particularly for blood flow imaging. While LSCI provides physicians with valuable insights into changes or occlusions in blood flow, the technique is susceptible to various factors and parameters that can impact measurement sensitivity and signal-to-noise ratio (SNR). These include the scattering of light, which can affect the quality and reliability of the LSCI data. The polarization of light holds significant promise to enhance the performance of LSCI. In this study, we employed polarization manipulation of light to investigate its impact on the performance of LSCI for measuring flow. Focusing on the application of LSCI in microcirculation within capillaries, we examined the effect of polarization control on the technique's flow measurement capabilities using a custom-designed phantom system. This phantom consisted of three tubes with inner diameters of 1.1 mm, 1.6 mm, and 2.8 mm, embedded in a polydimethylsiloxane (PDMS) matrix with optical properties similar to biological tissue. By manipulating the polarization of both the incident and reflected light, alternating between parallel and perpendicular states, we compared the performance of our LSCI system in detecting flow for different tube diameters and depths within the phantom. Our study revealed that while depth is a critical parameter influencing flow detection using LSCI, employing perpendicular polarization (between incident and reflected light) resulted in the lowest measurement error and highest SNR compared to parallel polarization and the absence of polarization control.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Confocal Fluorescence Microscopy


