Conjunctive optimal operation of water and power networks

Tomer Shmaya1, Mashor Housh2, Filippo Pecci3

  • 1Faculty of Civil and Environmental Engineering, Technion - Israel Institute of Technology, Haifa, 32000, Israel.

Heliyon
|November 5, 2024
PubMed

Related Concept Videos

Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
95
The Power Flow Problem and Solution01:26

The Power Flow Problem and Solution

Power flow problem analysis is fundamental for determining real and reactive power flows in network components, such as transmission lines, transformers, and loads. The power system's single-line diagram provides data on the bus, transmission line, and transformer. Each bus k in the system is characterized by four key variables: voltage magnitude Vk​, phase angle δk​, real power Pk​, and reactive power Qk​. Two of these four variables are inputs, while the...
174
Fast Decoupled and DC Powerflow01:24

Fast Decoupled and DC Powerflow

The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
176
Regulation of Water Output01:26

Regulation of Water Output

The human body predominantly expels water through the urinary system. On average, an individual generates around 1.5 liters of urine each day. This amount can fluctuate based on how well a person is hydrated, but a critical minimum quantity of urine must be produced to ensure the body's proper functioning. Daily, the kidneys remove 600 to 1200 milliosmoles of dissolved substances, effectively excreting excess minerals and water-soluble toxins such as creatinine, urea, and uric acid from the...
277
Energy Considerations in Open Channel Flow01:27

Energy Considerations in Open Channel Flow

Open channel flow, where a fluid flows with a free surface exposed to the atmosphere, is primarily governed by gravitational and surface effects, distinguishing it from closed conduit or pipe flow. In open channels such as rivers, canals, and artificial channels, energy analysis provides valuable insights into flow behavior and the relationship between depth, velocity, and slope.Specific Energy and Flow DepthIn open channel flow, the specific energy, E, combines the gravitational potential...
80
Control of Power Flow01:30

Control of Power Flow

There are several methods to control power flow in power systems:
253