Pacemaker lead extraction saved a severe lead-induced tricuspid regurgitation: a case report
YuLiang Chai1, Qiang Liu1, Zhiwen Chen1
1Department of Cardiology, Jiangxi Provincial People's Hospital, The First Affiliated Hospital of Nanchang Medical College, No. 92, Aiguo Road, Nanchang City, Jiangxi Province 330006, China.
Background:
Pacemaker lead-induced tricuspid regurgitation is a common complication after cardiac implantable electronic device (CIED) implantation. Cardiac implantable electronic device lead removal is a challenge procedure.
Case Summary:
A 72-year-old lady was admitted due to worsening heart failure. She had a history of permanent atrial fibrillation and had a permanent single-chamber pacemaker implanted 8 years ago due to complete heart block. Transthoracic echocardiography identified severe lead-related tricuspid regurgitation. The patient underwent successful lead extraction and received a new implantation of left bunch bundle area pacing. Transthoracic echocardiographic examination 2 days after the procedure showed a significant decrease of the tricuspid regurgitation. The patient also reported an improvement in heart failure symptoms.
Discussion:
Pacemaker lead-related tricuspid regurgitation introduces negative haemodynamic overload, carrying high risk for the development of heart failure and worse outcome. The present case shows a rapid relief of symptom and improvement of echocardiography findings, indicating the significance of mechanistic approach in the treatment of lead-related tricuspid mechanical interference.
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Introduction Cardiac Emergencies
Cardiopulmonary Resuscitation III: AED Use
Cardiomyopathy II: Dilated Cardiomyopathy
Cardiomyopathy III: Hypertrophic Cardiomyopathy
Cardiomyopathy V: Interprofessional Care