Related Experiment Video
Updated: Jun 8, 2025

Functional Near-Infrared Spectroscopy Hyperscanning Study in Psychological Counseling
Published on: January 17, 2025
Psychometric Properties of Chinese Version of the Barriers to Error Disclosure Assessment (C-BEDA) Tool
Rong-Rong Huang1, Yu-Sheng Xie2, Gui-Ru Chen3
1Department of Burns and Plastic Surgery, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, People's Republic of China.
Aim:
The Barriers to Error Disclosure Assessment (BEDA) tool is used to measure barriers to the disclosure of medical errors by healthcare professionals. This study aimed to evaluate the psychometric properties of the Chinese version of the BEDA (C-BEDA).
Background:
The culture of disclosure and transparency in response to medical errors has been recommended in recent years. However, there are no relevant assessment tools for measuring barriers to disclosing medical errors in China.
Methods:
The C-BEDA tool underwent translation, back translation, cross-cultural adaptation in a pilot study. It was tested with 1254 healthcare professionals in Guizhou and Sichuan Provinces, China. The content validity index (CVI) was used to evaluate the content validity of the C-BEDA, and exploratory factor analysis (EFA) and confirmatory factor analysis (CFA) were used to evaluate its structural validity. The Cronbach's α coefficient and test-retest reliability were evaluated to determine its reliability.
Results:
Three factors were extracted by EFA that explained 65.892% of the total variance of the C-BEDA tool. CFA showed a good fit for a three-factor structure with acceptable values: goodness-of-fit index=0.939; adjusted goodness-of-fit index=0.911; incremental fit index=0.967; comparative fit index=0.967; partial least squares path modeling for confirmatory factor analysis=0.735; and root mean square error of approximation=0.058. The item-level content validity index ranged from 0.86 to 1.00, and the average scale-level content validity index was 0.98. The Cronbach's α coefficient (0.909) and test-retest reliability (0.86) were acceptable.
Conclusion:
The C-BEDA toolis a valid and reliable tool for assessing the extent of barriers to error disclosure among Chinese healthcare professionals.
Related Concept Videos
Self-Report Tests of Personality
Self-Discrepancy Theory
Cattell's 16 Personality Factors
In contrast, source traits are the...
Reliability and Validity
Self-Presentation: Self-Monitoring and Self-Handicapping
Five-Factor Theory of Personality
Openness reflects creativity, curiosity, and openness to new experiences. Individuals scoring high in openness are imaginative, have a wide range of interests, and are independent...

