Cryptosporidium parvum inactivation from short durations of treatment with ozonated water produced by an electrolytic
Makoto Matsubayashi1,2,3, Asako Haraguchi4,5, Manami Morisaki4
1Graduate School of Veterinary Medical Sciences, Osaka Metropolitan University, Osaka, 598-8531, Japan. matsubayashi@omu.ac.jp.
Abstract:
Cryptosporidium is a waterborne pathogen that causes diarrhea in vertebrates and humans (mainly C. hominis and C. parvum). Ozone (O3) is a powerful disinfectant due to its high oxidative characteristics, and it is used to inactivate microorganisms in drinking water. As an alternative to the gas dissolution system for producing ozone from oxygen, a simpler electrolytic ozone generation system has recently been developed. In the present study, the efficacy of the ozonated water produced by this system in inactivating Cryptosporidium parasites (C. parvum) was evaluated at different current intensities (which change the ozone concentrations) and short exposure times (15-60 s). Oocyst viability and integrity was assessed using vital dye staining, excystation assays, and scanning electron microscopy (SEM). SEM data revealed that oocyst walls were damaged by exposure to ozone molecules even at low concentrations (< 0.01 mg/l for 1 min) (current intensity 0.2 A), but that the excystation assay could not differentiate between deformed oocysts (dead) and partially excysted oocysts (alive). Exposure to ozonated water produced with a low current intensity (0.3 A) for 15 and 120 s resulted in the inactivation of 96.2% (CT value < 0.003) and 99.4% (CT value < 0.020) of the oocysts, respectively. Thus, it was estimated that a CT value more than 0.020 was required to inactivate > 99% of the C. parvum oocysts. These results suggested that the electrolytic ozone generation system may be more effective than gas dissolution ozone generation; however, further studies using additional approaches are needed to obtain clearer evidence.
More Related Videos
14:17The Portable Chemical Sterilizer PCS, D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
05:31Studying Cryptosporidium Infection in 3D Tissue-derived Human Organoid Culture Systems by Microinjection
Published on: September 14, 2019
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Chemical Agents for Microbial Control