Three Different Protocols of Corneal Collagen Crosslinking in Keratoconus: Conventional, Accelerated and Iontophoresis
Published on: November 12, 2015
Determining the Relationship Between Corneal Stiffening and Tissue Dehydration After Corneal Cross-Linking
Raymundo Rodríguez-López1, Joshua N Webb1, Metecan Erdi2
1Fischell Department of Bioengineering, University of Maryland, College Park, Maryland, United States.
Purpose:
To quantify corneal cross-linking (CXL)-induced stiffening via mechanical testing to estimate the impact of changes in hydration levels (H) and evaluate depth-dependent tissue hydration after CXL.
Methods:
Eighty-three porcine corneal buttons were divided into three groups: Standard protocol CXL (S-CXL), accelerated CXL (A-CXL), and untreated (nonirradiated riboflavin-only) controls. Samples were hydrated or dehydrated to modulate H and dynamic mechanical analyzer compression tests were performed to measure Young's modulus (E). To extract the solid tissue network modulus, the cornea was modeled as a biphasic material after measuring E at different H. Corneal hydration was correlated with depth-dependent tissue thickness characterized by confocal reflection microscopy (CRM).
Results:
Young's modulus increased fourfold after S-CXL (0.72 ± 0.1 MPa) and threefold after A-CXL E (0.53 ± 0.12 MPa) versus controls (0.17 ± 0.045 MPa). However, H decreased from 4.07 ± 0.35 in controls to 2.06 ± 0.2 after S-CXL and 2.79 ± 0.12 after A-CXL. After H modulation and biphasic mechanical modeling, Young's modulus for corneal solid tissue network showed only a 1.8-fold increase after S-CXL (2.25 MPa) and 1.5-fold increase after A-CXL (1.85 MPa) versus controls (1.22 MPa). With CRM, the overall thickness of the corneal tissue was found to linearly correlate to hydration H as expected. No appreciable depth dependence of hydration-induced thickness changes throughout the corneal buttons were observed.
Conclusions:
Corneal tissue hydration changes significantly impact measured corneal stiffness after CXL using mechanical testing. Not considering H leads to major overestimation of the stiffening effect of the CXL procedure. Depth-dependence of corneal thickness because of changing hydration is strongly dependent on the integrity of the tissue.
More Related Videos
07:51Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts
Published on: October 21, 2022
04:48Establishing a Severe Corneal Inflammation Model in Rats Based on Corneal Epithelium Curettage Combined with Corneal Sutures
Published on: November 22, 2024
Related Concept Videos
Membrane Fluidity
Membrane Fluidity
Mosaic nature of the membrane
The mosaic characteristic of the membrane helps the plasma membrane remain fluid. The integral proteins and lipids exist as separate but loosely-attached molecules in the membrane. The membrane is a relatively...
Cell Motility through Blebbing
Blebbing Through the Matrix
In multicellular...
Mechanisms of Membrane Domain Formation
Another mechanism for membrane domain formation involves membrane proteins interacting with cytoskeletal...
Anchoring Junctions
Tight Junctions