Related Experiment Video
Updated: Jun 8, 2025

Setup of Consumer Wearable Devices for Exposure and Health Monitoring in Population Studies
Published on: February 3, 2023
Validity of a Consumer-Based Wearable to Measure Clinical Parameters in Patients With Chronic Obstructive Pulmonary
Fien Hermans1,2, Eva Arents1, Astrid Blondeel2
1Department of Rehabilitation Sciences, Ghent University, Corneel Heymanslaan 10, Entrance 46, Ghent, 9000, Belgium, 3293326915.
Background:
Consumer-based wearables are becoming more popular and provide opportunities to track individual's clinical parameters remotely. However, literature about their criterion and known-groups validity is scarce.
Objective:
This study aimed to assess the validity of the Fitbit Charge 4, a wrist-worn consumer-based wearable, to measure clinical parameters (ie, daily step count, resting heart rate [RHR], heart rate variability [HRV], respiratory rate [RR], and oxygen saturation) in patients with chronic obstructive pulmonary disease (COPD) and healthy controls in free-living conditions in Belgium by comparing it with medical-grade devices.
Methods:
Participants wore the Fitbit Charge 4 along with three medical-grade devices: (1) Dynaport MoveMonitor for 7 days, retrieving daily step count; (2) Polar H10 for 5 days, retrieving RHR, HRV, and RR; and (3) Nonin WristOX2 3150 for 4 nights, retrieving oxygen saturation. Criterion validity was assessed by investigating the agreement between day-by-day measures of the Fitbit Charge 4 and the corresponding reference devices. Known-groups validity was assessed by comparing patients with COPD and healthy controls.
Results:
Data of 30 patients with COPD and 25 age- and gender-matched healthy controls resulted in good agreement between the Fitbit Charge 4 and the corresponding reference device for measuring daily step count (intraclass correlation coefficient [ICC2,1]=0.79 and ICC2,1=0.85, respectively), RHR (ICC2,1=0.80 and ICC2,1=0.79, respectively), and RR (ICC2,1=0.84 and ICC2,1=0.77, respectively). The agreement for HRV was moderate (healthy controls: ICC2,1=0.69) to strong (COPD: ICC2,1=0.87). The agreement in measuring oxygen saturation in patients with COPD was poor (ICC2,1=0.32). The Fitbit device overestimated the daily step count and underestimated HRV in both groups. While RHR and RR were overestimated in healthy controls, no difference was observed in patients with COPD. Oxygen saturation was overestimated in patients with COPD. The Fitbit Charge 4 detected significant differences in daily step count, RHR, and RR between patients with COPD and healthy controls, similar to those identified by the reference devices, supporting known-groups validity.
Conclusions:
Although the Fitbit Charge 4 shows mainly moderate to good agreement, measures of clinical parameters deviated from the reference devices, indicating that monitoring patients remotely and interpreting parameters requires caution. Differences in clinical parameters between patients with COPD and healthy controls that were measured by the reference devices were all detected by the Fitbit Charge 4.
More Related Videos
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
00:07Home-Based Prescribed Pulmonary Exercise in Patients with Stable Chronic Obstructive Pulmonary Disease
Published on: August 24, 2019
Related Concept Videos
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Observational Studies
There are three types of observational studies – Prospective, retrospective, and cross-sectional.
Prospective Study
Prospective studies, also known as longitudinal or cohort studies, are carried out by collecting future data from groups sharing similar characteristics. One...
Chronic Obstructive Pulmonary Disease-I: Introduction
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...
Physical Assessment of the Respiratory Tract I: Health History
Subjective Data
Subjective data provides vital information about the patient's health history and symptoms. This data is typically collected through interviews in which patients describe their experiences, symptoms, and concerns.
Health history and...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...