Related Experiment Video
Updated: Jun 8, 2025

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
The effects of thoracic epidural blockade on ventilation-perfusion matching during one-lung ventilation: An
Yuxian Wang1, Yilin Wei2, Guannan Chen1
1Department of Critical Care Medicine, Zhongshan Hospital, Fudan University, Shanghai, China.
Objective:
Electrical impedance tomography (EIT) enables continuous image acquisition, facilitating real-time measurements of ventilation and perfusion at the clinical bedside. Experimental and clinical studies on controversial effects of thoracic epidural blockade (TEB) with local anesthetics on ventilation-perfusion(V/Q) matching and hypoxia during one lung ventilation (OLV) are rare. The aim of this study was to use EIT to investigate the effects of TEB combined with general anesthesia on pulmonary perfusion distribution and V/Q matching during one-lung ventilation.
Design:
Single-centered, prospective, unblinded, randomized, parallel-group clinical trial.
Setting:
Surgical suite of a university-affiliated teaching hospital.
Patients:
Thirty patients prepared for thoracic surgery were randomly assigned to either the control group or the TEB group, which received a combination of thoracic epidural blockade and general anesthesia.
Measurements:
EIT measurements and blood gas analysis were conducted in the lateral position during two-lung ventilation(T0), 15 min after OLV(T1), and 15 min after administration of 0.25 % ropivacaine or 0.9 % saline via epidural delivery during OLV(T2). Hemodynamic and respiratory parameters were recorded, and Dead Space%, Shunt%, and V/Q Match% were calculated based on blood gas analysis and EIT images.
Results:
Mean arterial pressure (p < 0.05) significantly decreased 15 min after TEB, while there were no significant changes in heart rate among the 30 patients (p = 0.547). OLV resulted in a significant decrease in arterial oxygen partial pressure/inspired oxygen fraction (PaO2/FiO2) from T0 to T1 in both groups. The PaO2/FiO2 in the TEB group was significantly lower after epidural administration of the local anesthetic (p < 0.05). Shunt- ABG (%) was significantly higher in the TEB group compared to the control group at T2 (p < 0.05). TEB increased non-ventilated perfusion distribution(p < 0.05), and Shunt-EIT % (p < 0.05) and reduced Matched Region % (p < 0.05), while Dead Space-EIT % remained (p = 0.499).
Conclusions:
Based on the contrast-enhanced EIT evaluation of pulmonary perfusion and ventilation, TEB appears to induce a V/Q mismatch in patients undergoing OLV in the lateral position for thoracic surgery.
Trial Registration:
ClinicalTrials.gov, NCT04730089. Registration on January 25th, 2021.
More Related Videos
Related Concept Videos
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Pneumothorax-II
Clinical Manifestations: