Related Experiment Video
Updated: Jun 8, 2025

Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Blood Pressure Variability and Ocular Vestibular-Evoked Myogenic Potentials Are Independently Associated With
Keun-Tae Kim1, Jeong-Heon Lee1, Jun-Pyo Hong1
1Department of Neurology, Korea University Medical Center, Seoul, Korea.
Background And Purpose:
We delineated the association between otolithic dysfunction and blood pressure (BP) variability.
Methods:
We prospectively recruited 145 consecutive patients (age=71 [59-79] years, median [interquartile range]; 76 females) with orthostatic intolerance between December 2021 and December 2023 at a tertiary hospital in South Korea. Each patient underwent evaluations of cervical and ocular vestibular-evoked myogenic potentials (oVEMPs), 24-h noninvasive ambulatory BP monitoring (ABPM), and a head-up tilt-table test using the Finometer device. As measures of BP variability, the standard deviations (SDs) of the systolic BP (SBPSD) and the diastolic BP were calculated based on serial ABPM recordings. Patients were divided into those with orthostatic hypotension (OH, n=68) and those with a normal head-up tilt-table test despite orthostatic intolerance (NOI, n=77) groups.
Results:
A multivariable logistic regression analysis showed that OH was associated with bilateral oVEMP abnormalities (p=0.021), SBPSD (p=0.012), and female sex (p=0.004). SBPSD was higher in patients with OH than in those with NOI (p<0.001), and was not correlated with n1-p1 amplitude (p=0.491) or normalized p13-n23 amplitude (p=0.193) in patients with OH. The sensitivity and specificity for differentiating OH from NOI were 72.1% and 67.5%, respectively, at a cutoff value of 12.7 mm Hg for SBPSD, with an area under the receiver operating characteristic curve of 0.73.
Conclusions:
Bilaterally deficient oVEMP responses may be associated with OH regardless of 24-h BP variability, reflecting the integrity of the otolith-autonomic reflex during orthostasis. Alternatively, 24-h BP variability is predominantly regulated by the baroreflex, which also participates in securing orthostatic tolerance complementary to the vestibulo-autonomic reflex.
Related Concept Videos
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart...
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Hypertension and Regulation of Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...
Factors affecting Blood pressure
Physiological Factors: