Related Experiment Video
Updated: Jun 8, 2025

Analyzing the Photo-oxidation of 2-propanol at Indoor Air Level Concentrations Using Field Asymmetric Ion Mobility Spectrometry
Published on: June 14, 2018
Indoor Air Quality Monitoring System with High Accuracy of Gas Classification and Concentration Prediction via
Xueqin Gong1, Zhipeng Li1, Liupeng Zhao1
1State Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, People's Republic of China.
Abstract:
The efficacy of sensors, particularly sensor arrays, lies in their selectivity. However, research on selectivity remains notably obscure and scarce. In this work, indoor pollutants (C7H8, HCHO, CH4, and NO2) were chosen as the target gas. Following the screening of six oxides from previous work, temperature-programmed desorption/reduction experiments were conducted to delve into the origins of selectivity. The results explicate the superiority of NiO in detecting toluene and unveil the distinctive NO2 sensing mechanism of WO3 sensors. Based on the sensor array comprising these oxides, it can clearly detect low concentrations of C7H8 (S = 1.6 to 50 ppb), HCHO (S = 1.4 to 50 ppb), and NO2 (S = 3.3 to 50 ppb), which satisfies the requisites of indoor air monitoring. Meanwhile, three machine learning models (Extreme Gradient Boosting, Support Vector Machine, and Back Propagation Neural Network) are employed for gas classification. The classification accuracies of these models are 95.45%, 100%, and 100%, while the R2 values of the concentration prediction are 99.65%, 94.9%, and 98.04%, respectively, indicating the rationality of material selection. Furthermore, it can still achieve relatively high accuracy in gas classification (94.12%) and concentration prediction (89.36%), even for gas mixtures of four gases. Finally, an indoor air quality monitoring system is developed, which enables real-time monitoring of indoor gas quality through the Internet of Things.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...

