On the trail of CBCT-guided adaptive rectal boost radiotherapy, does daily delineation require a radiation
Julien Pierrard1,2, David Dechambre2, Christel Abdel Massih2
1UCLouvain, Institut de Recherche Experimentale et Clinique (IREC), Center of Molecular Imaging, Radiotherapy and Oncology (MIRO), Brussels, Belgium.
Introduction:
Dose-escalation radiotherapy for rectal tumours is increasingly considered as a non-operative approach, with online-adaptive radiotherapy (oART) supporting this approach by correcting inter-fraction tumour position errors. However, using cone-beam computed tomography (CBCT)-guided oART requires daily target volume delineation by different operators, leading to inter-operator delineation variability and potential dosimetric issues. This study aims to compare and quantify the inter-operator and inter-professional delineation variability of the rectal boost volume on CBCT, including volumes by an automatically delineated oART treatment planning system.
Materials And Methods:
A rectal boost volume, defined as the primary tumour extended to the entire adjacent rectal wall, was delineated on 10 CBCTs from 5 patients by 15 operators: 4 expert radiation oncologists (ROs), 4 radiation therapists (RTTs) and 7 non-expert ROs. These contours were compared between the different professional groups. A comparison to the average volume of the group (ROs, RTTs, or non-expert ROs) with the lowest delineation variability was also performed for each individual volume including the volume automatically generated by an oART treatment planning system.
Results:
Delineation variability was the highest in the superior (range: 2.3-6.0 mm), and inferior (2.3-12.4 mm) directions, compared to the left (0.2-4.4 mm), right (0.3-2.0 mm), anterior (0.1-2.9 mm), and posterior (0.5-4.0 mm) directions. Non-expert ROs, RTTs, and automatic oART volume showed similar ranges of delineation errors when compared to the expert ROs' volume, which was chosen as reference volume since this professional group showed the lowest variability.
Discussion:
Expert ROs showed consistent results. Other professional groups exhibit similar variability, comparable to the automatic oART volume. Therefore, RTTs could safely perform the rectal boost delineation without non-expert ROs supervision in the absence of expert ROs during CBCT-based oART. Moreover, these findings provide quantitative data to compute accurate margins for the rectal boost planning target volume in a CBCT-guided oART workflow.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Imaging Studies III: Computed Tomography