Aim:
This study aims to evaluate the stress distribution on buccolingual and linguobuccal tilted implants in the atrophic posterior mandible using finite element analysis.
Material And Methods:
Twelve digital models of implants with varying lengths (8.5 mm, 10 mm, 11.5 mm) and angles (20°, 25°) were created. These implants were analyzed under 150 N vertical and oblique forces to assess stress distribution on both implants and surrounding bone.
Results:
Linguobuccal implants generally exhibited lower maximum principal stress in cortical bone, while buccolingual implants showed lower minimum principal stress. Longer implants reduced stress under oblique loading.
Conclusion:
Tilted implants, particularly using the linguobuccal method, are effective for stress distribution in the atrophic posterior mandible. Further research should explore varying implant diameters and multiple placements for optimization.
More Related Videos
05:54Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
07:16Author Spotlight: Development of a Novel Finite Element Analysis Model for Improved Orthognathic Surgical Techniques
Published on: October 20, 2023
Related Concept Videos
The Tongue and Taste Buds
Assessment of the Mouth
Mouth Inspection
The inspection begins with visually examining the mouth for symmetry, color, and size.