Related Experiment Video For Ambient light
Updated: Jul 11, 2026

Accuracy in Dental Medicine, A New Way to Measure Trueness and Precision
Published on: April 29, 2014
The effects of different lighting conditions on the accuracy of intraoral scanning
Mehmet Karakuzu1, Caner Öztürk2, Züleyha Başar Karakuzu3
1Department of Prosthodontics, Faculty of Dentistry, Hatay Mustafa Kemal University, Hatay, Turkey.
Purpose:
This study aimed to investigate the extent to which intraoral scanning are affected by clinical conditions, and whether ambient lighting and different color temperatures have an impact on the accuracy of intraoral scanner, as well as to evaluate scanning time.
Materials And Methods:
Twelve different environments were created using various ambient lighting conditions (0, 500, 1000 and 1500 lux) and color temperatures (white, blue and yellow). A partially edentulous mandibular model with two implants and a three-unit bridge was scanned under each environment until 10 digital models were obtained, and scanning times were recorded using a virtual stopwatch. A 3D analysis was performed on the obtained digital models, and the data were analyzed using a software. The generalized linear model analysis and Tukey multiple comparison test were used to analyse the data (P < .05).
Results:
The effect of lux, color temperature, and scanning times on RMS data was found to be significant (P < .001). The mean RMS value was the highest in the 0 lux group and the lowest in the 500 lux group. Regarding the color temperature, the highest RMS value was in the white color group and the lowest in the yellow color group. Scanning times were similar among the 0, 500 and 1000 lux groups, with a significant increase in the 1500 lux group.
Conclusion:
Different ambient lighting conditions and color temperatures have significant effect on the accuracy of intraoral scanning.
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Confocal Fluorescence Microscopy
Super-resolution Fluorescence Microscopy
Variables Affecting Phosphorescence and Fluorescence

