Discrepancy in the Diagnosis of Heart Failure With Preserved Ejection Fraction Between Supine Versus Upright Exercise
Marat Fudim1,2,3, Veraprapas Kittipibul1,2, Ashley Swavely1
1Department of Medicine (M.F., V.K., A.S., A.G., J. Mikitka, E.Y., O.D., M.R., J.F., J. Molinger, B.P.), Duke University Medical Center, Durham, NC.
Background:
Invasive exercise right heart catheterization is a gold standard in diagnosing heart failure with preserved ejection fraction (HFpEF). Body positions during the test influence hemodynamics. However, the discrepancy in HFpEF diagnosis between exercise testing in supine versus upright position is unknown.
Methods:
We conducted a 2-center prospective study enrolling patients referred for exercise right heart catheterization for HFpEF. We performed a Supright protocol integrating submaximal supine bicycle ergometry (20 W) followed by maximal upright bicycle ergometry with a breath-by-breath oxygen analyzer. HFpEF hemodynamic criteria specific to testing positions were applied. Patients were considered to have concordant HFpEF if they met criteria in both positions or discordant HFpEF if they met criteria only in the supine position.
Results:
Of 36 patients who met HFpEF criteria in supine position, 18 (50%) did not meet criteria in upright position (discordant HFpEF). Discordant HFpEF had less atrial fibrillation (0% versus 55%; P<0.001), lower left atrial volume (60±14 versus 77±21 mL; P=0.010), and lower H2FPEF score (2.1±1.3 versus 5.1±2.3; P<0.001). In supine position, pulmonary arterial wedge pressure was lower in discordant HFpEF at rest (15±4 versus 19±7 mm Hg; P=0.040). In upright position, pulmonary arterial wedge pressure was lower in discordant HFpEF both at rest (8±4 versus 14±6 mm Hg; P=0.002) and at peak exercise (14±4 versus 27±7 mm Hg; P<0.001). Pulmonary arterial wedge pressure/cardiac output slope was lower in discordant HFpEF (1.6±1.7 versus 3.6±2.9; P<0.001). Maximal workload (46±18 versus 49±24 W; P=0.59) or peak oxygen consumption (11.4±2.8 versus 12.9±3.4 mL/[kg·min]; P=0.15) was similar between groups.
Conclusions:
Half of patients who met HFpEF criteria in the supine position did not meet the criteria in the upright position. Patients with a discordant HFpEF phenotype had less structural and hemodynamic abnormalities compared with those with concordant HFpEF. A Supright exercise right heart catheterization approach is feasible and merits further investigation to determine the clinical implications of discordant exercise hemodynamic findings in supine and upright positions.
More Related Videos
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
08:37Echocardiographic Assessment Using Subxiphoid-Only Examination for Hypotensive Patients
Published on: April 18, 2025
Related Concept Videos
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Pathophysiology of Heart Failure
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies