Efficiency of infrared pyrometer and infrared thermography for assessing body surface temperature in hair sheep
Wilder Hernando Ortiz Vega1, Robson Mateus Freitas Silveira2, Ana Carolina Barros de Freitas1
1Laboratory for Animal Breeding and Genetic Improvement, Department of Veterinary Medicine, State University of North Fluminense (UENF), Campos dos Goytacazes, RJ 28013-602, Brazil.
Abstract:
The objectives of this study were: (i) to verify and compare the coat surface temperature (CST) of regions of interest (ROI) measured through infrared pyrometer (IRP) and thermography (IRT) under two environmental conditions, to evaluate (ii) reliability and (iii) sensitivity of the two infrared equipments to the environmental effect. Twenty hair ewes (Ovis aries), multiparous, non-lactating, non-pregnant, with body weight 59.38 ± 6.23 kg and body score condition ranging from 2.5 to 4.5 were evaluated. All CST, in both infrared methods, were higher (P < 0.001) in the afternoon (2 to 3 p.m.), with the exception of eyes surface temperature (TSEY) from IRT, which was higher (P < 0.001) in the morning (8 to 9 a.m.). Regarding the infrared methods at different times (twice a day, morning and afternoon), of the day, CST values for all ROIs were significantly higher (P < 0.001) in thermography, regardless of the time shift, except for ear pinna surface temperature (TSE) and rectum surface temperature (TSR), which showed no significant difference (P > 0.05) between the infrared methods during the morning shift. The thermal environment significantly influences (P < 0.001) the surface temperature of various anatomical regions in both infrared methods. The correlation coefficients between IRT and IRP were moderate. The IRT is more sensitive to the thermal environment, as it presented higher canonical coefficients in the environmental variables. Among surface temperatures, eye surface temperature is the most influenced by variables in the thermal environment, especially THI. All three methods (digital thermometer-DT, IRT and IRP) showed >80 % of the data variation in the first two components. Using the DT, we observed an association between vaginal temperature (VT) and RT with air temperature (AT) and temperature humidity index (THI), which was similar to the infrared thermography pattern, in which all ROIs were highly correlated with AT and THI. The opposite was observed in the pyrometer, in which an association between eye temperature and RH and lower factor loadings of the other ROIs with AT and THI in the first component was observed. In conclusion, while IRP and IRT showed similar performance in the morning, IRT proved to be more accurate in the afternoon, demonstrating a higher success rate in classifying the group of origin. Therefore, it is concluded that IRT is more reliable than IRP in detecting surface temperature changes under high temperatures.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...