Enhancing disturbance rejection in boost converter for CPL: A controller design approach with partial pole placement
Sarva Ruvinigya Somanshu1, Md Nishat Anwar1, Ramesh Kumar1
1Department of Electrical Engineering, National Institute of Technology Patna, Patna 800005, India.
Abstract:
In DC microgrids, the cascade operation of the DC-DC converters leads to a constant power load fed by the boost converter, resulting in unstable behavior in addition to the non-minimum phase dynamics. An enhanced load disturbance rejection control scheme based on partial pole placement and an approximate model matching technique is proposed. This approach is inspired by the well-known direct synthesis method to achieve optimal load disturbance rejection performance. The effectiveness of the proposed control scheme has been validated through hardware implementation, demonstrating its capability in setpoint tracking and load disturbance rejection under variations in load power and input voltage. The robust stability of the suggested scheme has been investigated through the Kharitonov theorem and Monte-Carlo simulation, considering different performance matrices. The suitability of the presented scheme has been established by analyzing the comparative performance of recently reported works. The proposed controller reduces peak overshoot and settling time by ∼50%, handles system uncertainties up to 75%, and outperforms FOPID controllers tuned with particle swarm optimization, queen bee genetic algorithm, and chaos game optimization methods.
More Related Videos
06:04Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
09:01Gain-compensation Methodology for a Sinusoidal Scan of a Galvanometer Mirror in Proportional-Integral-Differential Control Using Pre-emphasis Techniques
Published on: April 4, 2017
Related Concept Videos
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
PD Controller: Design
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
PI Controller: Design
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Phase-lead and Phase-lag Controllers