Strengthening Effect Evaluation of Developed Stiff-Type Polyurea Sprayed on Masonry Beam Surface Under Static Loading
Tae-Hee Lee1, Jang-Ho Jay Kim1
1School of Civil and Environmental Engineering, Yonsei University, 50, Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea.
Abstract:
Recently, deteriorated masonry structures aged over 30 years have shown serious structural problems. Simple and rapid maintenance plans are urgently needed for aging masonry structures. Polyurea (PU) is an effective retrofitting material for aging structures due to its easy spray application. This process saves time, reduces costs, and allows the structure to remain in use during retrofitting. However, a general PU is not suitable for retrofitting aged masonry and concrete structures due to its low stiffness. In this study, stiff-type polyurea (STPU) was selected as the reinforcement material for masonry structures. It was developed by modifying the chemical mix of general PU to improve stiffness. To evaluate the strengthening effect of STPU on masonry members under static loading, tests were conducted. The flexural load capacity of masonry beams with STPU-sprayed surfaces was assessed. Three different types of STPU applications were used to select the most efficient strengthening method. Reinforcing masonry structures with STPU allows brittle failure modes to achieve ductile behavior. This improves their structural performance under lateral stresses. The experimental data were used to calibrate FEM models for simulation. These models can be used for future parametric studies and masonry structural design.
Related Concept Videos
Reinforced Brick Masonry
To fortify brick walls...
Mortar Properties
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Masonry Loadbearing Walls
Posttensioned Masonry Walls
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...
Mortar Joint Deterioration in Masonry
The...