Related Experiment Video
Updated: May 12, 2026

A Rapid and Chemical-free Hemoglobin Assay with Photothermal Angular Light Scattering
Published on: December 7, 2016
Light-Sheet Skew Ray-Based Microbubble Chemical Sensor for Pb2+ Measurements
Tingting Zhuang1,2, Lukui Xu1, Mamoona Khalid3
1Shenzhen Key Laboratory of Ultrafast Laser Micro/Nano Manufacturing, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education/Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.
This study presents a novel multimode fiber sensor for detecting lead in water. The sensor achieves highly sensitive lead detection, reaching a detection limit well below the safety limit for drinking water.
Area of Science:
- Optoelectronics
- Chemical Sensing
- Nanotechnology
Background:
- Lead contamination in water poses significant health risks.
- Accurate and sensitive detection methods for lead are crucial for environmental monitoring.
- Existing methods may lack sensitivity or specificity for trace lead detection.
Purpose of the Study:
- To develop and demonstrate a highly sensitive multimode fiber-based sensor for detecting trace lead in contaminated water.
- To enhance sensor performance using optical phenomena and nanomaterials.
- To achieve a detection limit significantly lower than established safety guidelines.
Main Methods:
- Utilizing a light sheet to excite skew rays within a multimode fiber for optimized light absorption.
- Incorporating an inline microbubble structure to focus skew rays and intensify the evanescent field.
- Employing gold nanoparticles functionalized with oxalic acid to amplify the evanescent field and enhance specificity for lead ions via localized surface plasmon resonance (LSPR).
Main Results:
- The proposed sensor demonstrated significantly enhanced absorption sensitivity.
- Achieved a low detection limit of 0.1305 ng/mL for lead ions.
- The detection limit is substantially lower than the World Health Organization's safety limit of 10 ng/mL.
Conclusions:
- The developed multimode fiber sensor offers a highly sensitive and specific method for detecting trace lead in water.
- The combination of optical focusing, evanescent field enhancement, and LSPR provides a robust sensing platform.
- This technology has potential applications in environmental monitoring and water quality assessment.