Related Experiment Video
Updated: Jun 7, 2025

Adapted Resistance Training Improves Strength in Eight Weeks in Individuals with Multiple Sclerosis
Published on: January 29, 2016
Assessing and tailoring predictive equations of VO2max for women with multiple sclerosis with mild to moderate
Marco Morrone1, Anna Boi1, Lucia Ventura1
1Department of Biomedical Sciences, University of Sassari, Sassari, Italy.
Background:
Established equations to predict peak oxygen uptake (VO2max) in healthy subjects are not directly applicable to patient populations, including people with multiple sclerosis (PwMS). PwMS, who commonly exhibit impaired cardiorespiratory and neuromuscular function, often require tailored predictive models. This study aimed at (1) testing the validity, reliability, and accuracy of four widely used formulae, developed in healthy populations, to estimate VO2max in mildly to moderately disabled women with MS, and (2) develop adjusted formulae tailored on MS features.
Methods:
Fifty-one mildly to moderately disabled women (mean age 46, median EDSS 3.5) with relapsing-remitting multiple sclerosis (RRMS) underwent incremental cardiopulmonary exercise testing (CPET) using cycle ergometry. Gas exchanges were analyzed by open-circuit spirometry. Four commonly employed predictive equations (ACSM, Storer's, Uth's, and Myers') were tested for reliability and accuracy against measured VO2max. Regressions were performed to identify significant VO2max predictors and to introduce adjustments to develop gender-specific equations aimed at estimating cardiorespiratory fitness with varying degrees of exercise involvement.
Results:
ACSM and Storer's equations underestimated VO2max (-6.09 %, Z = -3.22, p = 0.001; and -21.74 %, Z = -5.02, p < 0.001, respectively) whereas Uth's and Myers' equations overestimated it (+20.19 %, Z = -5.92, p < 0.001; and +19.31 %, Z = -6.19, p < 0.001, respectively). Regressions for adjusted equations revealed work rate/bodyweight (WR/BW) (β = 0.867, p < 0.001) for ACSM adjusted; age (β = -0.275, p = 0.004), BW (β = -0.658, p < 0.001) and peak Watts (β = 0.485, p < 0.001) for Storer's adjusted; heart rate ratio (β = 0.512, p < 0.001) for Uth's adjusted, and age (β = -0.492, p < 0.001), BW (β = -0.483, p < 0.001) and EDSS (β = -0.211, p = 0.046) for Myers' adjusted as predictors of VO2max.
Conclusions:
VO2max can be validly estimated in women with MS using established formulae, provided that specific adjustments are introduced to account for their signature functional impairments. The models proposed in this study enable reliable assessment of cardiorespiratory fitness with protocols at different levels of exercise involvement, making them practical for clinical and everyday use. This approach supports a translationally driven bench-to-bedside perspective, allowing for patient VO2max assessment in virtually all settings.
More Related Videos
11:35The Multiple Sclerosis Performance Test MSPT: An iPad-Based Disability Assessment Tool
Published on: June 30, 2014
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Related Concept Videos
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: