Related Experiment Video
Updated: May 15, 2026

Evaluation of a Novel Laser-assisted Coronary Anastomotic Connector - the Trinity Clip - in a Porcine Off-pump Bypass Model
Published on: November 24, 2014
Duplex ultrasound as a single imaging test for Global Limb Anatomic Staging System assignment stage and comparison
Carlos Martínez-Rico1, Xavier Martí-Mestre1, Dorelly Martínez-Del Carmen1
1Department of Endovascular and Vascular Surgery, Hospital Universitari de Bellvitge, Hospitalet de Llobregat, Barcelona, Spain; IDIBELL, Institut Investigació Biomèdica de Bellvitge, Hospitalet de Llobregat, Barcelona, Spain.
Objective:
Obtaining a prognostic and predictive classification based on the risk of amputation is crucial in ischemic pathology of the lower limbs. Accurate anatomical characterization of arterial lesions is essential for optimal clinical decision-making. The Global Limb Anatomic Staging System (GLASS) provides a comprehensive anatomy assessment of the femoropopliteal and infrapopliteal arterial system. GLASS introduces concepts such as the target arterial path and estimated limb-based patency, crucial for determining the best arterial route to restore blood flow.
Methods:
A prospective study conducted from May to December 2022 involved 66 patients undergoing revascularization surgery for critical limb-threatening ischemia. Preoperative arterial mapping using duplex ultrasonography was the sole imaging modality. The target arterial path was defined in each patient, and GLASS staging was determined. Intraoperative arteriography was used on the day of surgery for comparison. Agreement between preoperative arterial mapping and intraoperative arteriography was assessed using Cohen's kappa coefficient, and diagnostic metrics were compared using receiver operating characteristic curves.
Results:
Doppler ultrasound demonstrated a sensitivity of 98%, specificity and positive predictive value of 100%, and negative predictive value of 94.7% in the femoropopliteal sector, with a Kappa coefficient of 0.98. For the infrapopliteal sector, sensitivity was 95%, specificity 96.5%, positive predictive value 97.3%, and negative predictive value 93.3%, with a Kappa coefficient of 0.89. Combining both sectors, the overall GLASS stage showed a 93.9% concordance with a Kappa coefficient of 0.91. Receiver operating characteristic curves revealed no significant differences between ultrasound and arteriography in terms of staging.
Conclusions:
This study demonstrates that Doppler ultrasound can serve as the exclusive imaging modality for determining the preoperative GLASS stage.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
07:03Imaging and Quantification of the Hepatic Vasculature of Mice Using Ultrafast Doppler Ultrasound
Published on: July 19, 2024
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Imaging Studies II: Ultrasonography
Imaging Studies VII: Vascular Imaging