Novel metrics for tracking blood pressure changes incontinuous cuffless blood pressure estimations
1Health Devices Research Group, School of Electrical Engineering and Computer Science, Faculty of Engineering, University of Ottawa, Ottawa, K1N 6N5, Canada. she014@uottawa.ca.
Abstract:
Recent studies revealed the importance of tracking continuous blood pressure (BP) changes in monitoring and controlling hypertension and diagnosing cardiovascular diseases. However, current evaluation protocols utilize distance measures as primary metrics, which cannot properly evaluate the ability of the estimation model to track BP changes. This paper proposes a comprehensive evaluation framework which evaluates the distance and trend similarity metrics, and the composite metric of both between the reference and estimated BPs. The results of applying both widely used conventional metrics and the new proposed metrics for BP estimations are demonstrated in an example of comparing the reference with a set of different BP estimations. Then, the metrics are applied to BP estimations obtained using state-of-the-art (SOTA) algorithms. It is shown that even though SOTA algorithms have a low mean and standard deviation of absolute difference, they are not capable of tracking short-term blood pressure changes. Additionally, the proposed metrics are normalized metrics and range from -1 to 1, making them intuitively interpretable, similar to well-known correlation coefficients. Therefore, we suggest that the proposed evaluation framework should be used regularly in evaluating continuous BP monitoring systems.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: