Point-Of-Care Ultrasound Screening for Proximal Lower Extremity Deep Venous Thrombosis
Published on: February 10, 2023
Pulse Wave Doppler Ultrasound in Unmasking of Venous Obstructions Highlighting Diagnostic Utility and Clinical
Shaheryar Usman1, Muhammad Cheema1, Saleem Mustafa1
1Department of Internal Medicine, Mather Hospital, Northwell Health, Port Jefferson, NY, USA.
Abstract:
Venous obstructions and thrombosis can present diagnostic challenges due to their varied presentations and potential for significant complications if untreated. Pulse wave doppler ultrasound via identification of damping or loss of cardiac pulsatility and/ or respiratory phasicity of venous waveforms serves as a practical, noninvasive, fast, and efficient diagnostic tool for identifying venous obstructions in the presence of compressible veins beyond the point of evaluation.We present two cases demonstrating the effectiveness of pulse wave doppler ultrasound in identifying significant and life-threatening venous obstructions. The first case involves a 68-year-old male with an incidental finding of a compressible left subclavian vein showing a monophasic waveform. Further investigation revealed significant compression of the left brachiocephalic vein by an aortic arch aneurysm. The second case describes a 65-year-old male with a compressible right femoral vein but a monophasic waveform, leading to the discovery of extensive thrombosis from the iliac veins to the inferior vena cava. This series proposes to always assess cardiac pulsatility and respiratory phasicity during doppler ultrasound procedure such as thyroid ultrasounds, deep vein thrombosis (DVT) evaluations, and pre-central vein catheterizations for identifying any venous obstructions, whether they are intrinsic or extrinsic, and for reducing the risk of thromboembolic complications.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse Assessment Sites
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...