Related Experiment Video
Updated: Jun 7, 2025

Sandy Soil Improvement through Microbially Induced Calcite Precipitation MICP by Immersion
Published on: September 12, 2019
Effect of water to cement ratio on mechanical properties of FRC subjected to elevated temperatures: Experimental and
M S Moradi1, M H Tavana1, M R Habibi1
1Department of Civil Engineering, Kermanshah Branch, Islamic Azad University, Kermanshah, Iran.
Abstract:
The deterioration of concrete is greatly dependent on the cracks and microcracks development owing to loading or environmental influences. An effective step to avoid the spread of cracks and microcracks is employing of different fibers in concrete and the manufacture of fiber reinforced concrete. On the other hand, fire is one of the cases that always threatens engineering structures. Elevated temperatures cause obvious chemical and physical changes that lead to concrete deterioration. In this study, the effect of adding various fiber with different volume contents in concrete mixture with various cement content was evaluated experimentally. Results indicate that spalling was more dominant in mixture containing steel fiber and with higher amount of cement, while there is not any spalling in mixture containing polypropylene (PP) fibers. Moreover, the reduction in tensile strength of fiber-free concrete specimens is less pronounced in mixtures with higher cement content. In addition, the positive performance of PP fibers compared to steel fibers was proved at higher temperatures and cement contents. Furthermore, by conducting a comprehensive and accurate survey, this research pinpoints gaps in the current literature. Moreover, the gathered dataset serves as input for training a machine learning approach known as Group Method of Data Handling (GMDH). The GMDH network demonstrates a satisfactory accuracy in predicting experimental results, with a MSE of 0.0044.
More Related Videos
Related Concept Videos
Water Cement Ratio
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...
Design Example: Managing Concrete Workability
Testing Water Quality
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Hot Weather Concreting
Mitigating the heat increase in concrete can be economically achieved by shading aggregate stockpiles to prevent heating from solar radiation,...