Multicriteria optimization achieves superior normal tissue sparing in volumetric modulated arc therapy for gastric
Ling He1, Xinrui Gao2, Tao Li2,3
1Department of Biotherapy, Cancer Center, West China Hospital, Sichuan University, Chengdu, 610041, China.
Objective:
To evaluate the benefits of volumetric modulated arc therapy (VMAT) based on multicriteria optimization (MCO) for gastric cancer patients, particularly the protection of serial organs at risk (OARs) that overlap with the target volume.
Methods:
MCO and single-criterion optimization (SCO) VMAT plans were conducted among 30 gastric cancer patients, with a prescription dose of 50.4 Gy delivered in 28 fractions. All treatment plans underwent review, and a comparison was made between the active planning time and different dose-volume parameters.
Results:
Both the MCO and SCO VMAT plans achieved the target dose coverage, with no significant difference in the conformity index (CI) for the planning target volume (PTV), at median CI values of 0.887 and 0.891, respectively (P = 0.417). The MCO plans showed a slight but significant increase in the homogeneity index of the PTV, with a median increase of 0.029 (P < 0.001). Additionally, the MCO plans resulted in a lower D2% to the small intestine and duodenum, with reductions of 3.43 Gy and 0.3 Gy, respectively (P < 0.05). Furthermore, the Dmax to the small intestine correlated moderately with the overlapping volume between the small intestine and the target volume (ρ = 0.42, P = 0.023). Except for the mean dose to the liver, the MCO plans performed better in terms of dose indicators for other OARs. Moreover, compared to the SCO plans, the median active planning time in the MCO plans was significantly reduced by 53.2 min (P < 0.0001).
Conclusions:
MCO can effectively help the physicians to quickly select an optimal treatment plan for patients with gastric cancer. It has been shown that MCO VMAT plans can significantly reduce the dose to OARs and shorten the active planning time, with acceptable target coverage. In addition, these plans take less dosimetric time, thereby streamlining the treatment planning process.