Programmed Intermittent Epidural Bolus vs Manual Epidural Bolus for Labor Analgesia Initiation: A Randomized
Yan Lu1, Yueqi Zhang1, Yuhan Zheng1
1Department of Anesthesiology, Shanghai Key Laboratory of Maternal Fetal Medicine, Shanghai Institute of Maternal-Fetal Medicine and Gynecologic Oncology, Shanghai First Maternity and Infant Hospital, School of Medicine, Tongji University, Shanghai, 200092, People's Republic of China.
Purpose:
Typically, labor analgesia is initiated with a manual loading dose. The programmed intermittent epidural bolus (PIEB) effectively maintains labor analgesia. However, no PIEB method has been studied for the initial loading dose. This study aimed to compare the effectiveness of loading doses administered via a PIEB versus a manual bolus.
Patients And Methods:
In total, 164 full-term singleton parturients were randomly assigned to receive a 12 mL loading dose (0.1% ropivacaine and 0.3 μg·mL-1 sufentanil) via manual or pump-driven injection. A standardized maintenance protocol was employed. The primary outcome was the percentage of parturients with adequate analgesia 20 min after the initial epidural injection. Adequate analgesia was defined as a numeric rating score (NRS) of ≤3 during two consecutive uterine contractions, without an additional analgesia request. Kaplan-Meier survival curves were constructed for the time interval needed to achieve adequate analgesia. A non-inferiority analysis was conducted by comparing the 90% confidence interval of the pain score difference with the non-inferiority margin.
Results:
The percentage of parturients achieving adequate analgesia was comparable (75.61% manual injection vs 76.83% pump injection, P=0.05 for non-inferiority). The median NRS was similar, except at 2 min (7 [5-8] manual injection vs 8 [6-9] pump injection, P=0.04). Median time to adequate analgesia, median ropivacaine consumption, median duration of epidural analgesia, incidence of requests for patient-controlled epidural analgesia (PCEA), median number of PCEA boluses, percentage of bilateral S2 blocks at 20 min, incidence of breakthrough pain, percentage of highest block level ≥T6 at 20 min, adverse effects, and obstetric and neonatal outcomes were similar between the groups.
Conclusion:
Within 20 min of administering a loading dose through a PIEB pump, non-inferior analgesia comparable to that achieved with manual injection was observed. This hands-free approach could help mitigate the impact of individual operational differences on analgesic efficacy.
Registration:
This trial was registered at chictr.org.cn (ChiCTR2300074063).
Related Concept Videos
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Local Anesthetics: Clinical Application as Spinal Anesthesia
Parenteral Anesthetics: Overview
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...
Drug Delivery: Parenteral Route
There are three primary parenteral routes: intravenous (IV), intramuscular (IM), and subcutaneous (SC). The IV route introduces the drug directly into the bloodstream, ensuring immediate action. The IM route...
Local Anesthetics: Clinical Application as Surface, Infiltration, and Conduction Block Anesthesia