Deciphering Isotopic Fine Structures of Silylated Compounds in Gas Chromatography-Vacuum Photoionization Orbitrap
Silvia Juliana Vesga Martínez1,2, Christopher P Rüger1,2, Paul Kösling1,2
1Joint Mass Spectrometry Centre (JMSC)/Chair of Analytical Chemistry, University of Rostock, 18059 Rostock, Germany.
Abstract:
We introduce vacuum resonance-enhanced multiphoton ionization (REMPI) with high-resolution Orbitrap Fourier transform mass spectrometry (FTMS) for analyzing silylated polar compounds. UV laser radiation at 248 nm sensitively and selectively targets aromatic constituents, while high-resolution mass spectrometry (HRMS) enables high-performance mass spectrometric detection. This workflow enhances the detection confidence of polar constituents by identifying unique isotopologue patterns, including at the isotopic fine structure (IFS) level, in analytical standards and complex bio-oils. A direct and derivatized gas chromatography (GC) procedure on a polar standard component mixture allowed us to explore the general ionization and detection characteristics of REMPI FTMS. HRMS enabled the examination of the complex isotopologue profiles, revealing distinct patterns for the CHOSi-class compounds. Particularly in complex mixtures, this isobaric/isonucleonic complexity exceeded the classical mass resolution capabilities of the employed Orbitrap D30 series and prompted the usage of prolonged transients via an external data acquisition system. This procedure substantially improved mass spectrometric results by recording the unreduced time-domain transient data for up to 2 s. Notably, the ability to distinguish diagnostic isotopic pairs, such as 12C/29Si vs 13C/28Si with a mass split of ∼3.79 mDa and 13C12C/28Si29Si vs 13C2/28Si2, with an approximate mass difference of ∼3.32 mDa, demonstrates a significant and expected performance improvement. Finally, we benchmark the GC HRMS methodology to identify silylated oxygenated and nitrogen-containing constituents in ultracomplex bio-oil samples. The presented approach of utilizing the silicon isotope pattern and unique isotopologue mass splits for increasing attribution confidence can be applied beyond bio-oils toward the general GC analyses of polar oxygenates.
More Related Videos
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
High-Resolution Mass Spectrometry (HRMS)
Mass Spectrometry: Isotope Effect
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Spectrometry: Cycloalkane Fragmentation
For example, cyclohexane molecular ions have a mass-to-charge ratio (m/z) of 84, which tends to produce a stronger signal than linear alkanes like hexane. This stability comes from...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...