Related Experiment Video
Updated: Jun 7, 2025

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Wearable System Integrating Dual Piezoresistive and Photoplethysmography Sensors for Simultaneous Pulse Wave
Borzooye Jafarizadeh1, Azmal Huda Chowdhury1, Md Shariful Islam Sozal1
1Department of Mechanical and Materials Engineering, Florida International University, Miami, Florida 33174, United States.
None:
Wearable, flexible piezoresistive pressure sensors have garnered substantial interest due to their diverse applications in fields such as electronic skin, robotic limbs, and cardiovascular monitoring. Among these applications, arterial full pulse waveform monitoring stands out as a critical area of research. The emergence of piezoresistive pressure sensors as a prominent tool for capturing pulse waveforms has led to extensive investigations. However, the lack of a linear response while achieving high sensitivity, limited compactness of signal collection systems, and scaling issues are a few potential causes of the gap between research advances and technology market readiness. Here, we present a scalable dual piezoresistive sensor that uses two complementary resistance-changing mechanisms to balance the trade-off between linear response and high sensitivity. This synergic design enables excellent sensitivity of 8.4 kPa-1 and near linear pressure response. It boasts a fast response time of 95/145 ms for loading and unloading at a pressure of 10.1 kPa. The durability tests, encompassing nearly 5000 two-stage compression cycles, validate the reliable performance of the sensor, even after prolonged use. Leveraging these performance metrics, we developed a high-resolution and compact signal collection device capable of accurately detecting the three distinct peaks associated with the full pulse waveform, including the systolic and reflected diastolic peaks. Moreover, the signal acquisition system incorporates a photoplethysmography sensor, which, when paired with the dual piezoresistive sensor, offers new insights into localized vascular health monitoring. The unique feature of our approach is its ability to perform localized vascular monitoring using multiple sensors placed on different veins. The simultaneous detection of forward- and backward-going pulse waves at the body extremities allows for a comprehensive evaluation of localized vascular health, which is not achievable with a single sensor. Finally, the comparison of wrist pulse waveforms between the compact signal collection device and a standard sourcemeter (such as the Keithley 2460) confirmed that the wearable sensing system is on par with conventional sourcemeters in terms of capturing the typical details of the full pulse waveform (i.e., systolic peak, dicrotic notch, and diastolic peak). This validation underscores the reliability and effectiveness of the developed wearable sensing system for practical and continuous pulse waveform monitoring.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse
The pulse serves as a clinical...
Special considerations while measuring pulse
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Holter Monitor: 24-Hour Monitoring

