Related Experiment Video
Updated: Jun 7, 2025

Highly Sensitive and Quantitative Detection of Proteins and Their Isoforms by Capillary Isoelectric Focusing Method
Published on: September 19, 2018
Fluorescein-based low-molecular-mass markers of isoelectric point for tracing pH gradient using high sensitivity
Pavlína Dadajová1, Richard Čmelík2, Karel Šlais2
1Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, Brno, 60200, Czech Republic; Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 5, Brno, 62500, Czech Republic.
Background:
Successful implementation of capillary isoelectric focusing (cIEF) in general requires the use of reference points - markers of isoelectric point. The low-molecular-mass fluorescent compounds based on the fluorescein structure, capable of marking distinct isoelectric points (pIs) with good focusing ability, stability, high extinction coefficient, and fluorescence are an alternative to the peptide and protein pI markers.
Results:
Four synthetic pathways were used to produce the ampholytic compounds and the structures along with their basic physical and chemical properties are given. Previously published low-molecular-mass pI markers were used to calibrate the candidate fluorescent compounds using capillary IEF (cIEF) with laser-induced fluorescence (LIF) detection. Linear and point-to-point pI calibration approach were compared for the pI evaluation. The results show 21 fluorescent pI markers (FPIMs). This group of markers covers pH range from 3.10 to 10.21. The usability of the developed FPIMs was further demonstrated by analysis of fluorescein isothiocyanate (FITC) labeled immunoglobin (IgG) standard. SIGNIFICANCE AND NOVELTY: pI markers are crucial for tracking the pH gradient and pI determination of biological ampholytic compounds. This paper presents and characterizes a novel pI marker set capable of tracing isoelectric points and supporting highly sensitive LIF detection-based applications. A basis of a newly developed cIEF-based fractionation method is described as well.
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary Electrophoresis: Instrumentation
Electrophoresis: Overview
There...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...