Related Experiment Video
Updated: May 12, 2026

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Five-year outcomes with self-expanding versus balloon-expandable TAVI in patients with left ventricular systolic
Masaaki Nakase1, Daijiro Tomii1, Annette Maznyczka1
1Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
Background:
The importance of transcatheter heart valve (THV) design on clinical outcome in patients with aortic stenosis (AS) and left ventricular (LV) systolic dysfunction remains unknown.
Objectives:
We aimed to compare 5-year outcomes of patients with severe AS and reduced LV ejection fraction (LVEF), undergoing transcatheter aortic valve implantation (TAVI) with balloon-expandable vs. self-expanding THVs.
Methods:
In a retrospective analysis from the Bern TAVI registry, patients with LVEF <50% who underwent TAVI with either balloon-expandable or self-expanding THVs were included. A 1:1 propensity-score matching was performed to account for baseline differences between groups.
Results:
A total of 759 patients were included between August 2007 and December 2022, and propensity-score matching resulted in 134 pairs. Technical success was achieved in over 85% of patients, and was similar in both groups. Self-expanding THVs were associated with a lower mean transvalvular gradient (7.1 ± 3.7 mmHg vs. 9.9 ± 4.3 mmHg; P < .001) and a higher incidence of ≥mild-to-moderate paravalvular regurgitation (36.3% vs. 11.3%; P < .001) compared to balloon-expandable THVs. At 5 years, patients treated with a self-expanding THV had higher all-cause mortality than those with a balloon-expandable THV (67.8% vs. 55.8%, HRadjusted: 1.44; 95% CI: 1.02-2.03; P = .037). There were no significant differences in other clinical outcomes up to 5 years between groups.
Conclusions:
In the setting of LV systolic dysfunction, patients treated with a self-expanding THV had higher risk of 5-year mortality compared to patients treated with a balloon-expandable THV.
Clinical Trial Registration:
https://www.
Clinicaltrials:
gov. NCT01368250.