Improved Diagnostic Performance Using Dual-Energy CT-Derived Slope Parameter Images in Crohn's Disease
Min Hong1, Ziying Lin2, Hua Zhong2
1Department of Radiology, Xiamen Cardiovascular Hospital of Xiamen University, School of Medicine, Xiamen University, No. 2999 Jinshan Road, Huli District, Xiamen, 361004, Fujian Province, China.
None:
The objective of the study is to explore the image quality and diagnosis performance of the dual-energy CT-derived slope parameter images (SPI) generated by the algorithm based on the slope function in the diagnosis of Crohn's disease (CD). Seventy-six CD patients and 53 disease-free control group subjects who underwent dual-energy CT enterography were retrospectively collected. Portal venous phase 120kVp-like and virtual monoenergetic images at 40-100 keV (VMI40-100) were reconstructed. SPIs corresponding to the spectral curve between 40 and 100 keV (SPI40-100) were generated using Python. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of normal and abnormal intestinal walls were calculated. Image quality, noise, and contrast were independently scored by two radiologists using a 5-point scale. Four radiologists conducted CD diagnosis with three reading models (120kVp-like, 120kVp-like with optimal VMI, and 120kVp-like with SPI40-100). The diagnostic performances of the three reading models for diagnosing CD were evaluated using receiver operating characteristic (ROC) curves. The CNR in SPI40-100 was higher than in the other images (P < 0.05). The subjective evaluation showed that there was no statistical difference between the contrast of SPI40-100 and VMI40 (P > 0.05), but that of the two images was higher than the other images (P < 0.05). The scoring on the overall image quality of VMI50 was superior to that of other images (P < 0.05). The combined model of 120kVp-like with SPI40-100 had the strongest confidence (cases with high confidence: 36, 58, 49, 47 for radiologists 1, 2, 3, 4) and the highest efficiency in diagnosing CD (areas under the ROC curve: 0.973, 0.977, 0.982, 0.991 for radiologists 1, 2, 3, 4). SPI40-100 generated by the algorithm based on the slope function exhibited good image quality. The combined model of 120kVp-like with SPI40-100 could improve radiologists' diagnostic efficiency and confidence in diagnosing CD.
More Related Videos
15:49Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...