Bayesian multi-exposure image fusion for robust high dynamic range ptychography
Abstract:
The limited dynamic range of the detector can impede coherent diffractive imaging (CDI) schemes from achieving diffraction-limited resolution. To overcome this limitation, a straightforward approach is to utilize high dynamic range (HDR) imaging through multi-exposure image fusion (MEF). This method involves capturing measurements at different exposure times, spanning from under to overexposure and fusing them into a single HDR image. The conventional MEF technique in ptychography typically involves subtracting the background noise, ignoring the saturated pixels and then merging the acquisitions. However, this approach is inadequate under conditions of low signal-to-noise ratio (SNR). Additionally, variations in illumination intensity significantly affect the phase retrieval process. To address these issues, we propose a Bayesian MEF modeling approach based on a modified Poisson distribution that takes the background and saturation into account. The expectation-maximization (EM) algorithm is employed to infer the model parameters. As demonstrated with synthetic and experimental data, our approach outperforms the conventional MEF method, offering superior phase retrieval under challenging experimental conditions. This work underscores the significance of robust multi-exposure image fusion for ptychography, particularly in imaging shot-noise-dominated weakly scattering specimens or in cases where access to HDR detectors with high SNR is limited. Furthermore, the applicability of the Bayesian MEF approach extends beyond CDI to any imaging scheme that requires HDR treatment. Given this versatility, we provide the implementation of our algorithm as a Python package.
More Related Videos
10:30Simultaneously Capturing Real-time Images in Two Emission Channels Using a Dual Camera Emission Splitting System: Applications to Cell Adhesion
Published on: September 4, 2013
07:13Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities
Published on: October 27, 2023
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Super-resolution Fluorescence Microscopy
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...