Related Experiment Video
Updated: Jun 7, 2025

Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection
Published on: February 1, 2022
Optimizing Carbon Structures in Laser-Induced Graphene Electrodes Using Design of Experiments for Enhanced
Fabiane Fantinelli Franco1, Muhammad Hassan Malik2, Libu Manjakkal3
1Water and Environment Group, Infrastructure and Environment Division, James Watt School of Engineering, University of Glasgow, Glasgow G12 8LT, U.K.
Abstract:
In this study, we explored the morphological and electrochemical properties of carbon-based electrodes derived from laser-induced graphene (LIG) and compared them to commercially available graphene-sheet screen-printed electrodes (GS-SPEs). By optimizing the laser parameters (average laser power, speed, and focus) using a design of experiments response surface (DoE-RS) approach, binder-free LIG electrodes were achieved in a single-step process. Traditional trial-and-error methods can be time-consuming and may not capture the interactions between all variables effectively. To address this, we focused on linear resistance and substrate delamination to streamline the DoE-RS optimization process. Two LIGs, designated LIG A and LIG B, were fabricated using distinct and optimized laser settings, which resulted in a sheet resistance of 25 ± 2 Ω/sq and 21 ± 1 Ω/sq, respectively. These LIGs, characterized by scanning electron microscopy, Raman spectroscopy, and contact angle analysis, exhibited a highly porous morphology with 13% pore coverage and a contact angle <50°, which significantly increased their hydrophilicity when compared to the GS-SPE. For the electrochemical studies, the oxidation of NO2- ion by the graphene-based working electrodes was investigated, as it allowed for the direct comparison of the LIGs to the GS-SPE. These included cyclic voltammetry, electrochemical impedance spectroscopy, and differential pulsed voltammetry studies, which revealed that LIG electrodes displayed a remarkable 500% increase in peak current during NO2- oxidation compared to the GS-SPE. The LIGs also demonstrated improved stability and sensitivity (420 ± 30 and 570 ± 10 nAμM-1 cm-2) compared to the GS-SPE (73 ± 4 nAμM-1 cm-2) in the oxidation of NO2- ions; however, LIG B was more susceptible to ionic interference than LIG A. These findings highlight the value of applying statistical approaches such as DoE-RS to systematically improve the LIG fabrication process, enabling the rapid production of optimized LIGs that outperform conventional carbon-based electrodes.

