Evaluation of Commercial-Off-The-Shelf Wrist Wearables to Estimate Stress on Students
Published on: June 16, 2018
Sensors: future tools for detecting young patient's stress during a dental invasive versus a non-invasive dental
C Jaldin1, C Jonasson2, T Fagrell1
1Public Dental Service, Region Vastra Gotaland, Gothenburg, Sweden.
Aim:
A reliable tool to visualise children's early stress signs to prevent dental fear development is needed. The aim was to evaluate the commercially available, CE marked, Shimmer3 GSR + unit's ability to indicate for stress as a reaction of fear or pain for a non-invasive dental treatment (NI) and an invasive dental treatment (I).
Methods:
Patients 14-16 years old were invited to undergo an oral check-up (NI) or an orthodontic premolar extraction (I), respectively. Digital data, measured via electrodes and optical pulse probe, placed on the wrist and fingers, monitored by the Shimmer3 GSR + unit, was transferred via Bluetooth to the HP-laptop. The observed digital parameters were: heart rate based on photoplethysmography (PPG), galvanic skin response (GSR), and 3-axis gyroscope and accelerometer signals for hand movements. Protocols for patient self-report scales were used: coloured analogue scale for pain intensity, facial analogue scale for the mood, and a dental fear scale. Descriptive statistics was performed.
Results:
The NI-group: 20 patients, (14.6 ± 0.5 years), underwent 20 oral check-ups. The I-group: 14 patients, (15.3 ± 0.5 years), underwent 28 premolar extractions. All patients tolerated the Shimmer3 GSR + unit well. The GSR signal increased significantly, at start and during the oral injection, in the I-group. The GSR amplitudes persisted throughout and post the dental injection. No general uniform pattern or high GSR amplitudes were produced regarding NI-group.
Conclusions:
Considering the limitations of this study, the following conclusions can be made: the invasive treatment resulted in a specific unison GSR pattern, while the non-invasive procedure showed individually scattered GSR reactions. The commercially available CE-marked Shimmer3 GSR + device indicated the patient's stress response triggered by the invasive anaesthetic procedure.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes